Hello, thanks for the input.  Everyones help is greatly appreciated. I
think we are going to scrutinize the non-twisted wire installed by the
gate contractor, the majority of you feel that is the culprit and I agree.
I hope I can help you one day.  Nick   Astech Security / Strategic Home
Media




> I guess I would be interested in what is on the other four conductors ;-)
>
> power maybe?  it only takes two conductors for the station port (t/r).  If
> the
> remaining four aren't being used, (earth) ground them at the ksu end,
> leave
> unconnected at the gate. also rf chokes at the gate connection might help
> limit noise.  a dsl microfilter works great for this.
>
> -larry
>
> 4/11/05 8:14:18 PM, [EMAIL PROTECTED] wrote:
>
>>It is about 450 feet on 18/6 solid.  We played with it again today and it
>>works great 20-30 times in a row and then locks up.  I think we
>> eliminated
>>the "only certain phones" theory also, it can happen on any system phone.
>>Thanks
>>
>>
>>> What kind of distance do you have between gate and ksu?
>>>
>>
>
>
>
>
> _________________________________________________________________
> KX-T Mailing list --- http://kxthelp.com/
> Subscription changes: http://kxthelp.com/mailman/listinfo/kxt
>



_________________________________________________________________
KX-T Mailing list --- http://kxthelp.com/
Subscription changes: http://kxthelp.com/mailman/listinfo/kxt

Reply via email to