If you did I wouldn’t get anything other than extended range temperature SFP. 
There’s also an activation code included with the SFP kit if I remember that 
you need.  

Jon Langeler
Michwave Technologies, Inc.


> On Jun 26, 2020, at 3:09 PM, Josh Luthman <j...@imaginenetworksllc.com> wrote:
> 
> 
> Can I use any SFP for the 450m 3ghz?
> 
> Josh Luthman
> Office: 937-552-2340
> Direct: 937-552-2343
> 1100 Wayne St
> Suite 1337
> Troy, OH 45373
> 
> 
>> On Fri, Jun 26, 2020 at 11:45 AM dave <dmilho...@wletc.com> wrote:
>> We have installed dozens of these so I wanted to chime in. 
>>  First off the difference on connecting up a 5Ghz vs 3.65ghz 450m 
>> 5Ghz will use only POE and has an aux port and a SFP port 
>> 3.65Ghz has a DC Port with 4pin connector. It also has a main,aux and SFP 
>> port. 
>> In order for any of them to use sync the main port must have Cambium Sync to 
>> it. 
>> 
>> We have started using the DC card packetflux has to power and control the 
>> 450m 3.65 radios.
>> I have  not had any issues by doing so, but we do run the main,aux and fiber 
>> ports for data and aux control. 
>> 
>> One of the thing we do to ensure long term reliability is installing the DC 
>> Lpus on all cables that use the Cat6 Armored cables 
>> we also install the DC Lpus for the DC ports. We also have inline fuses to 
>> each dc port. 
>> A tip is also add the cable ground kits if your running the armored cable up 
>> the tower. 
>> 
>> We see 300 to 400Mbs of traffic on a couple of our medusas that are cbsd's 
>> at 30mhz wide 
>> 
>> Fiber never looked so good on those ports LOL :)
>> 
>>  
>> 
>> <Vcard.jpg>
>>> On 6/25/20 11:45 AM, Steve Jones wrote:
>>> Im confused as shit, and the cambium documentation is not clear. The 
>>> syncinjector cambium sync says 450m, but is the only 450m 5ghz? the 3ghz as 
>>> bestI can tell is a DC only product (even says something about sync over 
>>> power)
>>> 
>>> so will the syncinjector still provide sync at the ethernet port, i just 
>>> turn off the power output on the syncinjector? or am i misunderstanding 
>>> this and the 450m 3ghz will take power via the ethernet port?
>>> 
>>> forrest?
>>> 
>>> 
>>> 
>>> 
>> 
>> -- 
>> AF mailing list
>> AF@af.afmug.com
>> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
> -- 
> AF mailing list
> AF@af.afmug.com
> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to