Can I use any SFP for the 450m 3ghz?

Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373


On Fri, Jun 26, 2020 at 11:45 AM dave <dmilho...@wletc.com> wrote:

> We have installed dozens of these so I wanted to chime in.
>  First off the difference on connecting up a 5Ghz vs 3.65ghz 450m
> 5Ghz will use only POE and has an aux port and a SFP port
> 3.65Ghz has a DC Port with 4pin connector. It also has a main,aux and SFP
> port.
> In order for any of them to use sync the main port must have Cambium Sync
> to it.
>
> We have started using the DC card packetflux has to power and control the
> 450m 3.65 radios.
> I have  not had any issues by doing so, but we do run the main,aux and
> fiber ports for data and aux control.
>
> One of the thing we do to ensure long term reliability is installing the
> DC Lpus on all cables that use the Cat6 Armored cables
> we also install the DC Lpus for the DC ports. We also have inline fuses to
> each dc port.
> A tip is also add the cable ground kits if your running the armored cable
> up the tower.
>
> We see 300 to 400Mbs of traffic on a couple of our medusas that are cbsd's
> at 30mhz wide
>
> Fiber never looked so good on those ports LOL :)
>
>
>
> On 6/25/20 11:45 AM, Steve Jones wrote:
>
> Im confused as shit, and the cambium documentation is not clear. The
> syncinjector cambium sync says 450m, but is the only 450m 5ghz? the 3ghz as
> bestI can tell is a DC only product (even says something about sync over
> power)
>
> so will the syncinjector still provide sync at the ethernet port, i just
> turn off the power output on the syncinjector? or am i misunderstanding
> this and the 450m 3ghz will take power via the ethernet port?
>
> forrest?
>
>
>
>
> --