Dear Takanori,
Thank you for your help. The issue is now resolved. I regret not
recognizing the minor error earlier.
I will be more careful about not sending screenshots of errors in the
future
Best regards,
Preeti
On Wed, Mar 12, 2025 at 6:56 AM Takanori Nakane <
tnakane.prot...@osaka-u.ac.
Hi,
Your file name contains space: "E1 11-2-25 URAC.tif".
This is not allowed. Please remove space from file names.
Also please don't use screenshots to show textual error messages.
Copy and paste them as texts next time.
Best regards,
Takanori Nakane
On 2025/03/11 22:18, Preeti wrote:
Dear
Dear Takanori,
Thank you for your help. I was doing exactly as you mentioned, but with
RELION 4.0.1. I will try it with RELION 5.0 instead
On Tue, Mar 11, 2025 at 5:19 PM Takanori Nakane <
tnakane.prot...@osaka-u.ac.jp> wrote:
> Hi,
>
> I cannot reproduce your problem.
> I did (with RELION 5.0
Hi,
I cannot reproduce your problem.
I did (with RELION 5.0):
1. Import: make sure to set "Are these multi-frame movies:" No.
2. Manual picking: select "Import/jobXXX/micrographs.star".
Best regards,
Takanori Nakane
On 3/11/25 20:29, Preeti wrote:
Hello everyone,
I am currently encountering