Hi Mehrdad,
Am 04.02.2025 um 11:03 schrieb Mehrdad Ravanbod:
Hi
I have come up against a seemingly difficult problem
Running Bacula 15.0.2 on a Redhat 9 clone, backing up windows
machines(via winows agents) to a network share(well, trying to), so I
want to back up from the windows machines
Hi Marco,
> I start all virtual full on sunday morning, at the same time. dummy
> autochanger have 3 devices.
> First job start and consume a device to read.
> Second job start consume a device to read.
> Third job start consume the last device to read.
> Device finished. No free device to write.
Tiny bit of additional information here -- I just learnt that actidata
https://www.actidata.com/index.php/en-gb/ is not averse to help with
Tandberg products. Limited possibilities, probably Europe only, and
definitely not as part of any original vendor support or even warranty,
but at least yo
Am 07.01.2025 um 05:35 schrieb Christophe PEREZ via Bacula-users:
Hi Arno,
Thanks.
I didn't even think that you could not designate any files in the
fileSet.
The documentation says
"There can be any number of Include resources within the FileSet," and
of course zero is also in that set :-)
Hi Christophe,
Am 06.01.2025 um 22:36 schrieb Christophe PEREZ via Bacula-users:
Hi,
With Bacula 15.0.2, is it possible in your opinion, to create a
completely dummy job?
That's possible and not uncommon... more or less for exactly the reason
you mentioned, just use a file set that has no ac
Hi Marco,
Am 03.01.2025 um 22:24 schrieb Marco Gaiarin:
I know that i'm not the only one here that use Overland-Tandberg products,
more specifically NEO tape library.
Good luck...
We have got 'rumors' from our local dealer that O-T is on bankruptcy; we
Insolvency with restructuring since
Hi Rob (and all),
Am 02.01.2025 um 18:14 schrieb Rob Gerber:
Arno,
Thank you very much for your reply and advice. I will investigate "
Allow Duplicate Jobs" and look at adding a runscript with 'whoami /all'
to my windows clients.
I can suggest something like
JobDefs {
Name = "DefaultJob"
Hi Rob,
Am 30.12.2024 um 04:34 schrieb Rob Gerber:
Happy new year, everyone!
I have a testing environment that I'm assembling for a client. Bacula
15.0.2, running in a rocky linux vm on a synology DS423+.
I have tested backups with a windows FD using a windows VM running
windows 11. This we
Hello Borut,
Am 21.12.2024 um 13:52 schrieb Borut Rozman via Bacula-users:
Hi there,
This question might be answered somewhere but I didn’t find the proper source
to find it out.
It may not be answered explicitly, but all the needed capabilities are
simply part of the core Bacula feature set
Hi all,
Am 13.12.2024 um 13:01 schrieb Martin Simmons:
On Fri, 13 Dec 2024 10:23:18 +0100, Arno Lehmann via Bacula-users said:
As I couldn't really understand what Martin referred to I had another,
closer look :-)
I noticed that Bill's decoded lstats ended up with ctimes of
Hi Rob, all,
Am 13.12.2024 um 13:02 schrieb Rob Gerber:
Everyone,
Thank you very much for all the help with this interesting problem and
for your advice.
Arno,
that query very quickly returned 443123 lines. Looking through them,
some were longer than others.
Indeed. the 59 characters was n
Hi all,
Am 13.12.2024 um 06:28 schrieb Marcin Haba:
...
Your notice about too long mtime is fully right. It is because the
lstat string is broken. Two lstat values are joined together and it
causes this wrong result. If we split them, then the decoded values
are more realistic and the number of
Hi Daniel,
Am 27.11.2024 um 21:43 schrieb White, Daniel E. (GSFC-764.0)[AEGIS] via
Bacula-users:
... about bacula-web, which I have not looked at for a *very* long time.
But:
200~Bacula-Web logo Bacula-Web
Oops, it looks like something went wrong somehow :(
Database error
SQLSTATE[0800
Hi,
Am 25.11.2024 um 15:10 schrieb Mehrdad Ravanbod:
Hi guys
bacula install pages for the community edition(actualy the whole site)
at Bacula.lat
bacula.lat is the turf of a company in Brazil (mostly) and the operators
are not very active here.
I would suggest reaching out via mail: cont.
Hi Mehrdad, all,
Am 19.11.2024 um 10:11 schrieb Eric Bollengier via Bacula-users:
Hello Mehrdad,
On 11/19/24 09:30, Mehrdad Ravanbod wrote:
...
I am still concerned about the databse and how much it will grow on a
yearly basism and the storage needed for the database tables, i am
planning on
Hi Roberto,
Am 11.11.2024 um 14:53 schrieb Roberto Greiner:
Hi,
just a quick upgrade question. I intend to upgrade my production server
from Ubuntu 22.04 to Ubuntu 24.04. Bacula is already at current release
(15.0.2). Besides replacing the name of the release in the apt/sources
file, should
te it ;-)
(But keep in mind there are no votes anyway...)
Cheers,
Arno
Thanks for the time you spent answering.
-Message d'origine-
De : Arno Lehmann via Bacula-users
Envoyé : mardi 5 novembre 2024 12:45
À : bacula-users@lists.sourceforge.net
Objet : Re: [Bacula-users] fileset
Hi Lionel,
Am 05.11.2024 um 11:31 schrieb Lionel PLASSE:
Hello,
I recently move a full directory form D: to G:
I change my FileSet Accordingly with IgnoreFilesetChanges option.
But, the next Incremental backup will fully backup the directory as it is a
new Path.
That's expected behaviour -
Hi Aaron,
Am 15.10.2024 um 20:49 schrieb Aaron Baxter:
I've encountered yet another issue with my Bacula install (using Ubuntu
jammy/22.04 packages). I created my storage tape drive, am able to
mount, unmount and label the tape volume but when I start a backup, it
gives the below logs and doe
Hu Mehrdad,
Am 14.10.2024 um 12:16 schrieb Mehrdad R.:
Hi Guys, i am wondering if it is possible to do this ?
I have tried this and it does not seem to work, i set FD to run on
port 9104 and SD on 9105(these are on a windows server), director runs
on 9101 as usual on another machine, behind a fi
20 matches