Bill, I thought that option was only available in the moraine version...


On Feb 27, 2013, at 6:05 PM, "Bill Coleman" <colt...@verizon.net> wrote:

> It is assessing the pressure to see if it is in the kick-in range.
> You can adjust the fleeb setting inside the switch for the delay setting.
>  
> Bill Coleman
> C&C 39 <image001.gif>
>  
> From: CnC-List [mailto:cnc-list-boun...@cnc-list.com] On Behalf Of Terry
> Sent: Wednesday, February 27, 2013 5:49 PM
> To: cnc-list@cnc-list.com
> Subject: Stus-List Water Pump delayed start
>  
> Hello, I have just installed a new fresh water pump. The new pump does not 
> come on right way as it is supposed to, instead it takes 15 to 45 seconds for 
> it to start. I thought it was a faulty pressure switch so I took the first 
> new pump back and installed a second new pump. The same problem occurs.
>  
> Any suggestions as to what the problem may be??
>  
> Terry Johnson
> S/V Ozymandias
> E-mail: tj...@comcast.net
> Website: www.tj622.com
> _______________________________________________
> This List is provided by the C&C Photo Album
> http://www.cncphotoalbum.com
> CnC-List@cnc-list.com
_______________________________________________
This List is provided by the C&C Photo Album
http://www.cncphotoalbum.com
CnC-List@cnc-list.com

Reply via email to