I would care if it blew up for no reason or if there was water ingress
through a crummy seal.
On 10/7/2021 1:45 PM, Mathew Howard wrote:
Yeah, I don't really see a good reason to not just use a surge
suppressor. Cheap-rate Ubiquiti or Mimosa suppressors can be had for
~$10... and you obviously aren't going to care much about the quality
of the actual surge suppression in this case anyway.
On Thu, Oct 7, 2021 at 12:28 PM Adam Moffett <[email protected]
<mailto:[email protected]>> wrote:
I guess both indoor and outdoor? Bonding for R56 compliance and also
for maybe getting RF noise to ground without going through our switch.
I suppose indoor we can hack it, and outdoor might as well use the
surge
suppressor. I'd imagine the housing and glands and such is more
money
than the PCB so there's nothing gained by paring it down.
-Adam
On 10/7/2021 12:56 PM, Chuck McCown via AF wrote:
> Trim back the jacket and attach a ground wire. Are you wanting
> something for outdoor mounting? It would have to be two shielded
> jacks and you would have to use shielded plugs on it. So two
jacks on
> a pcb and then some kind of housing.
>
> -----Original Message----- From: Adam Moffett
> Sent: Thursday, October 7, 2021 10:45 AM
> To: AnimalFarm Microwave Users Group
> Subject: [AFMUG] Ethernet ground block
>
> Is there an equivalent to the cable TV ground blocks but for Cat5?
>
> I would basically look like a coupler with a ground wire
attached to the
> shield. Much more basic than a surge suppressor.
>
> -Adam
>
>
>
--
AF mailing list
[email protected] <mailto:[email protected]>
http://af.afmug.com/mailman/listinfo/af_af.afmug.com
<http://af.afmug.com/mailman/listinfo/af_af.afmug.com>
--