Cherif.  I will attempt to take a stab at a few of your questions.  Don't take 
my answers as 100% right....

1 - All the blocks run at the same rate, but I am pretty sure you can implement 
an MMCM within your block to lower the rate for your needs and then back up to 
the crossbar rate.  Don't quote me, but I feel like I had this conversation 
with someone a few years back on the mailing list.
2 - The ADC/DAC are tied to the master clock rate (in the case of the X310, 
either 186.32MHz, or 200MHz)
3 - I don't believe so unless you do what I mentioned in the first comment.

All that said, I believe a lot of stuff can be tweaked under the hood, but it 
is hard to say what that will break, and it isn't exactly supported.

________________________________
From: USRP-users <usrp-users-boun...@lists.ettus.com> on behalf of Cherif Diouf 
via USRP-users <usrp-users@lists.ettus.com>
Sent: Thursday, February 28, 2019 10:05 AM
To: usrp-users@lists.ettus.com
Subject: [USRP-users] Hardware clocks, X310


Hello guys,



I am a researcher working with the X310 USRP. I have a couple of questions 
regarding the Hardware clocks.

The bus_clock and radio_clk are by default respectively set at 166 MHz and 200 
MHz.

And if I am right the crossbar clock ce_clk is also at 200 MHz. Is there a 
solution to bring it down to ce_clk = 50 MHz, in that case

1)      Does it mean that all the Kintex XC410T blocks will run at 50 MHz ? Is 
this safe?

2)       What about the ADC and DAC and their sampling clock?

3)      Finally can we have different RFnoc blocks running at different clock 
frequencies and still have the  crossbar  running at a given clock frequency?



Best Regards

Cherif