On Fri, May 03, 2019 at 07:43:06PM +0200, Philippe Reynes wrote: > The function bcm6345_wdt_start use the argument timeout > as tick but it should be used as milliseconds. > > A clock is added as requirement for this driver. > The frequency of the clock is then used to convert the > millisecond to ticks in the function bcm6345_wdt_start. > > Signed-off-by: Philippe Reynes <philippe.rey...@softathome.com> > Reviewed-by: Stefan Roese <s...@denx.de>
Applied to u-boot/master, thanks! -- Tom
signature.asc
Description: PGP signature