On 03.05.19 19:43, Philippe Reynes wrote:
The watchdog should use a clock at 50 Mhz, so
instead of using the clock osc (200 Mhz), we
define a reference clock at 50Mhz and use it
for both watchdog.
Just curious: Why is this the case? Is this also what's done in
the Linux DT version?
Other than that:
Reviewed-by: Stefan Roese <s...@denx.de>
Thanks,
Stefan
Signed-off-by: Philippe Reynes <philippe.rey...@softathome.com>
---
arch/arm/dts/bcm6858.dtsi | 10 ++++++++--
1 file changed, 8 insertions(+), 2 deletions(-)
diff --git a/arch/arm/dts/bcm6858.dtsi b/arch/arm/dts/bcm6858.dtsi
index 76ba0ea..91f7787 100644
--- a/arch/arm/dts/bcm6858.dtsi
+++ b/arch/arm/dts/bcm6858.dtsi
@@ -66,6 +66,12 @@
clock-frequency = <200000000>;
u-boot,dm-pre-reloc;
};
+
+ refclk50mhz: refclk50mhz {
+ compatible = "fixed-clock";
+ #clock-cells = <0>;
+ clock-frequency = <50000000>;
+ };
};
ubus {
@@ -92,13 +98,13 @@
wdt1: watchdog@ff802780 {
compatible = "brcm,bcm6345-wdt";
reg = <0x0 0xff802780 0x0 0x14>;
- clocks = <&periph_osc>;
+ clocks = <&refclk50mhz>;
};
wdt2: watchdog@ff8027c0 {
compatible = "brcm,bcm6345-wdt";
reg = <0x0 0xff8027c0 0x0 0x14>;
- clocks = <&periph_osc>;
+ clocks = <&refclk50mhz>;
};
wdt-reboot {
Viele Grüße,
Stefan
--
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: s...@denx.de
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
https://lists.denx.de/listinfo/u-boot