I just connected a Valcom 1030C horn speaker to paging port 1 on a KX-TD
1232-6. I cannot get this to work.
I am using icm 330 to try and page via the new speaker. Is this
correct? In the programming, under Musinc and Paging, it shows External
Paging 1 as Ext 196. If I try using Ext 196, I
320 - all external pagers
330 - all page groups
32 - n= external pager number (1 for KX-TD816 /1 through 4 for KX-TD1232)
33 - n= page group (1-8)
32* or 33* - pages everything
The floating numbers (196, etc.) are only used for feature access, like
from a DISA call, etc.
HTH,
Michael
BTW, you
I use Bogen amps - page 1 for inside, page 2 for outside. I believe
ICM 330 is for page 1, ICM 331 is for outside; I know ICM 33* is for
both. Try ICM 33* - that works the best here, 330 is low for some
reason. I used shielded cable with the center conductor to tip,
shield to ring at the amp.
3 matches