On Saturday, 15 December 2007 16:02:40 -0500,
Michael Galloway wrote:
> > Now I'm trying to perform backups operations. I've noticed when I
> > try label a volume, Bacula uses the slot 0 and then it causes a
> > mount error.
> > *label
> > Automatically selected Storage: DLTDrive
> > Enter new V
Hello,
13.12.2007 16:51,, Daniel Bareiro wrote::
> On Thursday, 13 December 2007 09:58:55 +0100,
> Arno Lehmann wrote:
>
>> Hi,
>
> Hi Arno. Thanks for your response.
>
>>> This is my first mail to the list. I'm newbie with Bacula.
>
>> I noticed that, when looking at the configuration ;-)
>
On Sat, Dec 15, 2007 at 05:44:20PM -0300, Daniel Bareiro wrote:
>
> The test autochanger worked!!
> --
>
> All the tests seems finished successfully!!
>
> Well, it's a good step in the correct direction :-)
>
> Now I'm trying to perform backu
On Friday, 14 December 2007 13:05:58 -0500,
Michael Galloway wrote:
> > I've performed the btape test according to Bacula's manual but I got
> > a message saying Bacula doen't found the medium.
> > [...]
> looks like either the changer script or mtx cannot get a tape from the
> library into the
On Fri, Dec 14, 2007 at 01:39:40PM -0300, Daniel Bareiro wrote:
> Hi Michael. I've performed the btape test according to Bacula's manual
> but I got a message saying Bacula doen't found the medium.
>
> sparky:~# btape -c /etc/bacula/bacula-sd.conf /dev/nst0
> Tape block granularity is 1024 bytes.
On Friday, 14 December 2007 14:09:27 +,
Allan Black wrote:
> I use an HP SureStore 718, which is very similar to the L280 (2 internal
> slots and exactly the same 6-slot cartridge with the hinged handle). If
> you like, I could post the relevant bits of my Bacula configuration, and
> you could
On Friday, 14 December 2007 06:19:44 -0500,
Michael Galloway wrote:
> daniel, were you able to successfully complete the btape test
> command from the bconsole? if it encounters errors it can
> suggest modifications to you configuration which may help.
Hi Michael. I've performed the btape test a
I use an HP SureStore 718, which is very similar to the L280 (2 internal
slots and exactly the same 6-slot cartridge with the hinged handle). If
you like, I could post the relevant bits of my Bacula configuration, and
you could use that as a starting point.
>> 3912 Failed to label Volume: ERR=dev.
daniel, were you able to successfully complete the btape test
command from the bconsole? if it encounters errors it can
suggest modifications to you configuration which may help.
-- michael
On Thu, Dec 13, 2007 at 12:51:46PM -0300, Daniel Bareiro wrote:
>
> I modified the autochanger resource d
On Thursday, 13 December 2007 09:58:55 +0100,
Arno Lehmann wrote:
> Hi,
Hi Arno. Thanks for your response.
> > This is my first mail to the list. I'm newbie with Bacula.
> I noticed that, when looking at the configuration ;-)
The humor sense in a mailing list always is welcome :-)))
> > I'm
in addition to what others have already indicated, i would suggest
working thru the tape and library section of the manual (i just
went through this exercise myself with a new library). have a look
here:
http://bacula.org/dev-manual/Testing_Your_Tape_Drive.html
make sure btape test works correctl
Hi,
13.12.2007 02:52,, Daniel Bareiro wrote::
> Hi all!
>
> This is my first mail to the list. I'm newbie with Bacula.
I noticed that, when looking at the configuration ;-)
> I'm using
> Bacula version (1.38.11-8) from Debian Etch for Sparc respositories.
I recommend upgrading to 2.2.6, even i
On Dec 12, 2007 8:52 PM, Daniel Bareiro <[EMAIL PROTECTED]> wrote:
> Hi all!
>
> This is my first mail to the list. I'm newbie with Bacula. I'm using
> Bacula version (1.38.11-8) from Debian Etch for Sparc respositories.
>
> The operating system detects the tape library and I can operate it with
>
13 matches
Mail list logo