On Dec 12, 2007 8:52 PM, Daniel Bareiro <[EMAIL PROTECTED]> wrote:
> Hi all!
>
> This is my first mail to the list. I'm newbie with Bacula. I'm using
> Bacula version (1.38.11-8) from Debian Etch for Sparc respositories.
>
> The operating system detects the tape library and I can operate it with
> mt and mtx:
>
> sparky:~# cat /proc/scsi/scsi
> Attached devices:
> Host: scsi0 Channel: 00 Id: 00 Lun: 00
>   Vendor: SEAGATE  Model: ST318404LC       Rev: 0002
>   Type:   Direct-Access                    ANSI SCSI revision: 03
> Host: scsi0 Channel: 00 Id: 06 Lun: 00
>   Vendor: TOSHIBA  Model: XM6201TASUN32XCD Rev: 1103
>   Type:   CD-ROM                           ANSI SCSI revision: 02
> Host: scsi3 Channel: 00 Id: 01 Lun: 00
>   Vendor: HP       Model: C6280-7000       Rev: 2.10
>   Type:   Medium Changer                   ANSI SCSI revision: 02
> Host: scsi3 Channel: 00 Id: 02 Lun: 00
>   Vendor: QUANTUM  Model: DLT7000          Rev: 296D
>   Type:   Sequential-Access                ANSI SCSI revision: 02
>
> sparky:~# mtx -f /dev/sg2 status
>   Storage Changer /dev/sg2:1 Drives, 8 Slots ( 0 Import/Export )
> Data Transfer Element 0:Empty
>       Storage Element 1:Full
>       Storage Element 2:Full
>       Storage Element 3:Full
>       Storage Element 4:Full
>       Storage Element 5:Full
>       Storage Element 6:Full
>       Storage Element 7:Full
>       Storage Element 8:Full
>
> sparky:~# mt -f /dev/st0 status
> SCSI 2 tape drive:
> File number=-1, block number=-1, partition=0.
> Tape block size 0 bytes. Density code 0x0 (default).
> Soft error count since last status=0
> General status bits on (50000):
>  DR_OPEN IM_REP_EN
>
> But checking the status storage from the Baculas's console delays long
> time without returns some results.
>
> sparky:/etc/bacula# ps ax|grep bacula|grep -v grep
> 24604 ?        Ss     0:00 /usr/sbin/bacula-dir -c
> /etc/bacula/bacula-dir.conf -u bacula -g bacula
> 24605 ?        S      0:00 /usr/sbin/bacula-dir -c
> /etc/bacula/bacula-dir.conf -u bacula -g bacula
> 24606 ?        S      0:00 /usr/sbin/bacula-dir -c
> /etc/bacula/bacula-dir.conf -u bacula -g bacula
> 24607 ?        S      0:00 /usr/sbin/bacula-dir -c
> /etc/bacula/bacula-dir.conf -u bacula -g bacula
> 25467 ?        Ss     0:00 /usr/sbin/bacula-sd -c
> /etc/bacula/bacula-sd.conf -u bacula -g tape
> 25469 ?        S      0:00 /usr/sbin/bacula-sd -c
> /etc/bacula/bacula-sd.conf -u bacula -g tape
> 25470 ?        S      0:00 /usr/sbin/bacula-sd -c
> /etc/bacula/bacula-sd.conf -u bacula -g tape
> 25471 ?        S      0:00 /usr/sbin/bacula-sd -c
> /etc/bacula/bacula-sd.conf -u bacula -g tape
>
> sparky:/etc/bacula# bconsole
> Connecting to Director sparky.educ.gov.ar:9101
> 1000 OK: maquinadirectora-dir Version: 1.38.11 (28 June 2006)
> Enter a period to cancel a command.
> *status
> Using default Catalog name=MyCatalog DB=bacula
> Status available for:
>      1: Director
>      2: Storage
>      3: Client
>      4: All
> Select daemon type for status (1-4): 2
> The defined Storage resources are:
>       1: respaldadora-sd
>       2: File
> Select Storage resource (1-2): 1
> Connecting to Storage daemon respaldadora-sd at sparky.educ.gov.ar:9103
> [ ... delays long time without returns some results ... ]
>
>
> The permissions over devices are corrects.
>
> sparky:~# ll /dev/st0 /dev/sg2
> crw-rw---- 1 root tape 21, 2 2007-12-12 11:54 /dev/sg2
> crw-rw---- 1 root tape  9, 0 2007-12-12 11:54 /dev/st0
>
> sparky:~# id bacula
> uid=105(bacula) gid=105(bacula) grupos=105(bacula),26(tape)
>
> In the bacula-sd.conf:
>
> Autochanger {
>   Name = Autochanger
>   Device = Drive-1
>   Device = Drive-2
>   Device = Drive-3
>   Device = Drive-4
>   Device = Drive-5
>   Device = Drive-6
>   Device = Drive-7
>   Device = Drive-8
>   Changer Command = "/etc/bacula/scripts/mtx-changer %c %o %S %a %d"
>   Changer Device = /dev/sg2
> }
>
> Device {
>   Name = Drive-1                  #
>   Drive Index = 0
>   Media Type = DLT-7000
>   Archive Device = /dev/nst0
>   AutomaticMount = yes;               # when device opened, read it
>   AlwaysOpen = yes;
>   RemovableMedia = yes;
>   RandomAccess = no;
>   AutoChanger = yes
>   Alert Command = "sh -c 'tapeinfo -f %c |grep TapeAlert|cat'"
> }
>
> [...]
>
> Device {
>   Name = Drive-8                    #
>   Drive Index = 0
>   Media Type = DLT-7000
>   Archive Device = /dev/nst0
>   AutomaticMount = yes;               # when device opened, read it
>   AlwaysOpen = yes;
>   RemovableMedia = yes;
>   RandomAccess = no;
>   AutoChanger = yes
>   Alert Command = "sh -c 'tapeinfo -f %c |grep TapeAlert|cat'"
> }
>
> Any idea to resolve this issue?
>

You need to define 1 device and not 8 because you have only 1 tape drive.

John

-------------------------------------------------------------------------
SF.Net email is sponsored by:
Check out the new SourceForge.net Marketplace.
It's the best place to buy or sell services
for just about anything Open Source.
http://ad.doubleclick.net/clk;164216239;13503038;w?http://sf.net/marketplace
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to