. Dezember 2014 10:02
An: Ana Emília M. Arruda
Cc: bacula-users@lists.sourceforge.net
Betreff: Re: [Bacula-users] update slots re
Ana Emília M. Arruda
Cc: bacula-users@lists.sourceforge.net
Betreff: Re: [Bacula-users] update slots reports Autochanger has 0 slots
Hello Ana,
What I recently experienced was "Autochanger has 0 slots" error when
"AutoChanger = yes" line is missing in Device directive in
. Arruda"
Kime: "Rainer Hackel"
Kk: "Süleyman Kuran" , "Can Şirin" ,
bacula-users@lists.sourceforge.net
Gönderilenler: 4 Aralık Perşembe 2014 23:35:37
Konu: Re: [Bacula-users] update slots reports Autochanger has 0 slots
Hello Rainer,
Can you try chang
rr...@gmail.com]
Gesendet: Donnerstag, 4. Dezember 2014 22:36
An: Rainer Hackel
Cc: Süleyman Kuran; Can Şirin; bacula-users@lists.sourceforge.net
Betreff: Re: [Bacula-users] update slots reports Autochanger has 0 slots
Hello Rainer,
Can you try changing Device Name? You have Name and Media Type using t
f %c |grep TapeAlert|cat'"
>
> Spool Directory = /data/bacula-spool
>
> Maximum File Size = 12GB
>
> Maximum Spool Size = 3200G
>
> # Maximum Block Size = 200
>
> }
>
>
>
> Do you have an other idea?
>
> Rainer
>
>
>
&
mum Block Size = 200
}
Do you have an other idea?
Rainer
Von: Süleyman Kuran [mailto:sku...@ayk.gov.tr]
Gesendet: Donnerstag, 4. Dezember 2014 19:23
An: Can Şirin
Cc: bacula-users@lists.sourceforge.net
Betreff: Re: [Bacula-users] update slots reports Autochanger has 0 slots
Merhaba Can,
Konu: Re: [Bacula-users] update slots reports Autochanger has 0 slots
Hi,
Check this posts:
http://www.freebsddiary.org/tape-library.php
http://www.freebsddiary.org/tape-library-integration.php
Same issue were discussed before.
(http://sourceforge.net/p/bacula/mailman/bacula-users/thread/2013
Hi,
Check this posts:
http://www.freebsddiary.org/tape-library.php
http://www.freebsddiary.org/tape-library-integration.php
Same issue were discussed before.
(http://sourceforge.net/p/bacula/mailman/bacula-users/thread/20130306100525.gd22...@nionex.net/)
Quoting Rainer Hackel :
Hello Bacula
che...@gmail.com]
Gesendet: Donnerstag, 4. Dezember 2014 15:17
An: Rainer Hackel
Cc: bacula-users@lists.sourceforge.net
Betreff: Re: [Bacula-users] update slots reports Autochanger has 0 slots
> But:
>
> “/usr/libexec/bacula/mtx-changer /dev/changer slots” reports 16
>
>
>
> Of co
> But:
>
> “/usr/libexec/bacula/mtx-changer /dev/changer slots” reports 16
>
>
>
> Of course the Autochanger has 16 slots.
>
> Someone has an idea?
>
Does user bacula have the permission to run mtx-changer, mtx and
access the device node for the autochanger?
John
---
Hello Bacula users,
Have some problems with a Quantum SuperLoader 3 LTO-6, and try to break them
down in small pieces... here is one:
"update slots" command in bconsole says:
Automatically selected Catalog: MyCatalog
Using Catalog "MyCatalog"
Automatically selected Storage: Autochanger
Connecting
On Fri, Feb 08, 2013 at 09:40:28AM -0500, Dan Langille wrote:
> On 2013-02-08 05:17, Uwe Schuerkamp wrote:
> I take it that your tape library does not read barcodes? Or that you
> are not
> using barcodes. Which is it?
Hi Dan, thanks much for your answer.
Our library is unable to read barcode
On 2013-02-08 05:17, Uwe Schuerkamp wrote:
> Hi folks,
>
> I'm about to use the "update slots scan" bconsole command for the
> first time as I'm fed up with doing all the manual work changing a
> set
> of tapes involves.
I take it that your tape library does not read barcodes? Or that you
are n
Hi folks,
I'm about to use the "update slots scan" bconsole command for the
first time as I'm fed up with doing all the manual work changing a set
of tapes involves.
In a perfect (bacula) world, this command would achieve the following:
- load all tapes in the changer one after the other
-
-BEGIN PGP SIGNED MESSAGE-
Hash: SHA1
Hi all,
I'm running Bacula 5.0.0-9.el6 from the CentOS 6 base repository.
My 24 slot autochanger with barcode reader died on me, and in order
to keep backups going I replaced it with a spare unit that has only
8 slots and no barcode reader. After the
On 27.05.2011 14:03, John Drescher wrote:
> On Fri, May 27, 2011 at 7:51 AM, Andre Lorenz wrote:
>> On 27.05.2011 09:41, Mauro Colorio wrote:
>>> what's the result of tapeinfo -f /dev/sg6 ?
>>>
>>> ciao
>>> Mauro
>> i changed something ;-)
>> reconfigured some stuff but noc change :-(
>>
>> lsscsi
On Fri, May 27, 2011 at 8:00 AM, Andre Lorenz wrote:
>
> mtx -f /dev/sg5 unload 11 0
> Unloading drive 0 into Storage Element 11...mtx: Request Sense: Long
> Report=yes
> mtx: Request Sense: Valid Residual=no
> mtx: Request Sense: Error Code=70 (Current)
> mtx: Request Sense: Sense Key=Illegal Req
On Fri, May 27, 2011 at 7:51 AM, Andre Lorenz wrote:
>
> On 27.05.2011 09:41, Mauro Colorio wrote:
>> what's the result of tapeinfo -f /dev/sg6 ?
>>
>> ciao
>> Mauro
> i changed something ;-)
> reconfigured some stuff but noc change :-(
>
> lsscsi -g
> ...
> [1:0:0:0] mediumx NEC LL0101H-0
mtx -f /dev/sg5 unload 11 0
Unloading drive 0 into Storage Element 11...mtx: Request Sense: Long
Report=yes
mtx: Request Sense: Valid Residual=no
mtx: Request Sense: Error Code=70 (Current)
mtx: Request Sense: Sense Key=Illegal Request
mtx: Request Sense: FileMark=no
mtx: Request Sense: EOM=no
mtx
On 27.05.2011 09:41, Mauro Colorio wrote:
> what's the result of tapeinfo -f /dev/sg6 ?
>
> ciao
> Mauro
i changed something ;-)
reconfigured some stuff but noc change :-(
lsscsi -g
...
[1:0:0:0]mediumx NEC LL0101H-0A 0002 /dev/sch0 /dev/sg2
[1:0:1:0]tapeIBM ULTRIUM-
> lsscsi -g
> ...
> [1:0:0:0] mediumx NEC LL0101H-0A 0002 /dev/sch0 /dev/sg2
> [1:0:1:0] tape IBM ULTRIUM-TD2 38D0 /dev/st0 /dev/sg3
>
> [2:0:0:0] tape IBM ULTRIUM-TD4 7A31 /dev/st1
> /dev/sg4 <- Drive 1
> [2:0:0:1] mediumx NEC T4
Hi,
i just got it back half working :-(
dmesg | grep 2:0:1:1
[ 79.677949] scsi 2:0:1:1: Medium ChangerNEC T40A2
0005 PQ: 0 ANSI: 2
[ 80.449402] ch 2:0:1:1: Attached scsi changer ch1
[ 80.449402] ch 2:0:1:1: Attached scsi generic sg6 type 8
[13387.819021] scsi 2:0:1:1: Med
try this
dmesg | grep 2:0:1:1
it will tell you the name of the device where the loaders is attached
(sg3 in my case)
then
mtx -f /dev/sg3 status
if it works check ur config files
Mauro
--
vRanger cuts backup time in h
On Wed, May 25, 2011 at 10:27 AM, Andre Lorenz wrote:
> Hello together,
>
> i have a NEC-LTO4 (FC) 40 slots changer, and 8 slot LTO2 (8 Slots)
> changer (SCSI).
>
> this one was working perfectly.
>
> after physical move of the changers and servers i cant run anymore
> update slots scan on the LT
Hello together,
i have a NEC-LTO4 (FC) 40 slots changer, and 8 slot LTO2 (8 Slots)
changer (SCSI).
this one was working perfectly.
after physical move of the changers and servers i cant run anymore
update slots scan on the LTO4 :-(
on the old LTO2 i can run it without any problems.
lsscsi will
Hello :-)
The issue seems to be with vchanger 0.8.5 and auto-mounting; it may be
specific to Slackware 13.0.
After disabling auto-mounting, manually mounting the USB HDD and
reconfiguring Bacula sd to suit, the "label barcodes" command worked.
Best
Charles
-Original Message-
From:
Hello :-)
This cross-posted from the vchanger mailing list because the problem cause
may be in either bacula-sd or vchanger -- or both, or neither if it's my
error as is most likley :-)
I'm setting up bacula 5.0.1 with vchanger 0.85 following the (very good,
thanks) procedure in vchangerHowto.
Robert Horton wrote:
> Hi,
>
> I've noticed that running "update slots" marks as added any volumes
> which have been added to the autochanger but doesn't mark as removed any
> which have been removed. Here's a sample output:
>
> *update slots
> Automatically selected Storage: Autochanger
> Connec
Hi,
I've noticed that running "update slots" marks as added any volumes
which have been added to the autochanger but doesn't mark as removed any
which have been removed. Here's a sample output:
*update slots
Automatically selected Storage: Autochanger
Connecting to Storage daemon Autochanger at f
Ok, so I can use "update slots" on an autochanger where barcode reader
and barcode labels are available; whenever the former or the latter is
missing I had to launch a full inventory of the library with "update
slots scan".
I guess the best practice is to label all the available volumes and then
r
Hi,
15.12.2008 17:34, John Drescher wrote:
>> Opening the mtx-changer script (bacula 2.2.6)..
>> ..
>> # list list Volume names (requires barcode reader) <- I
>> don't have one..is it necessary?
>> ..
> It's not necessary but in this case bacula has to read every single
> tape t
> Opening the mtx-changer script (bacula 2.2.6)..
> ..
> # list list Volume names (requires barcode reader) <- I
> don't have one..is it necessary?
> ..
It's not necessary but in this case bacula has to read every single
tape to determine the tapes label and update the database.
t 20:Empty
Storage Element 21:Full
Storage Element 22:Full
Storage Element 23:Full
Storage Element 24:Full
Thanks,
Massimo
- Original Message -
From: John Drescher
Date: Sunday, December 14, 2008 8:59 pm
Subject: Re: [Bacula-users] Update slots
To: Massimo Scheno
On Sun, Dec 14, 2008 at 2:24 PM, Massimo Schenone wrote:
> Hi all,
> when I get an unexpected behaviour when using the command update slots:
>
> *update slots
> Automatically selected Storage: SunSTK-C2
> Connecting to Storage daemon SunSTK-C2 at splinter:9103 ...
> Connecting to Storage daemon Su
Hi all,
when I get an unexpected behaviour when using the command update slots:
*update slots
Automatically selected Storage: SunSTK-C2
Connecting to Storage daemon SunSTK-C2 at splinter:9103 ...
Connecting to Storage daemon SunSTK-C2 at splinter:9103 ...
3306 Issuing autochanger "slots" command.
This
is probably well documented somewhere and I can't just find it.
real quick.
When I run 'update slots barcode' on my debian bacula director the tape
drive ejects puts the tape back into its original slot and then scans
all autochanger slots.
When I run 'update slots barcode' on my win3
Bob Hetzel wrote:
>> => *update slots
>> => Automatically selected Storage: Dell-PV136T
>> => Enter autochanger drive[0]: 0
>> => Connecting to Storage daemon Dell-PV136T at gyrus:9103 ...
>> => 3306 Issuing autochanger "slots" command.
>> => Device "Dell-PV136T" has 0 slots.
>> => No slots in cha
> Date: Wed, 27 Feb 2008 10:17:05 -0500
> From: [EMAIL PROTECTED]
>
> In the message dated: Tue, 26 Feb 2008 19:12:38 EST,
> The pithy ruminations from Bob Hetzel on
> <[Bacula-users] Update slots causes bacula console to prompt for drive, etc?>
> w
> ere:
&
In the message dated: Tue, 26 Feb 2008 19:12:38 EST,
The pithy ruminations from Bob Hetzel on
<[Bacula-users] Update slots causes bacula console to prompt for drive, etc?> w
ere:
=> I just noticed this oddity. Perhaps it's how I've got bacula
And which version of b
On Tue, Feb 26, 2008 at 7:12 PM, Bob Hetzel <[EMAIL PROTECTED]> wrote:
> I just noticed this oddity. Perhaps it's how I've got bacula
> configured, but it otherwise seems to work properly. I've got an
> autochanger with 72 slots and two tape drives. I just added some new
> tapes in and did th
I just noticed this oddity. Perhaps it's how I've got bacula
configured, but it otherwise seems to work properly. I've got an
autochanger with 72 slots and two tape drives. I just added some new
tapes in and did the following...
*update slots
Automatically selected Storage: Dell-PV136T
Enter
On Wed, Dec 12, 2007 at 11:12:17AM -0500, John Drescher wrote:
> > *update slots
> > The defined Storage resources are:
> > 1: LTO4
> > 2: File
> > Select Storage resource (1-2): 1
> > Connecting to Storage daemon LTO4 at molbio:9103 ...
> > 3306 Issuing autochanger "slots" command.
> > D
On Wed, Dec 12, 2007 at 11:12:17AM -0500, John Drescher wrote:
> > unmount
> > (remove magazine)
> > (insert new magazine)
> > update slots
> > mount
> >
> > however, when i run update slots i get this:
> >
> > *update slots
> > The defined Storage resources are:
> > 1: LTO4
> > 2: File
>
> good day all, i was doing some moving of cartridges and magazines in my
> T50, following
> this from the manual:
>
> f your autochanger has barcodes (machine readable tape labels), the task
> of informing Bacula is simple. Every time, you change a magazine, or add
> or remove a cartridge from the
On Dec 12, 2007 10:20 AM, Michael Galloway <[EMAIL PROTECTED]> wrote:
> good day all, i was doing some moving of cartridges and magazines in my T50,
> following
> this from the manual:
>
> f your autochanger has barcodes (machine readable tape labels), the task of
> informing Bacula is simple. Ev
good day all, i was doing some moving of cartridges and magazines in my T50,
following
this from the manual:
f your autochanger has barcodes (machine readable tape labels), the task of
informing Bacula is simple. Every time, you change a magazine, or add or remove
a cartridge from the magazine,
I've got bacula 1.38.9 (under Linux, with the director and sd daemons running on
the same server) using a Dell LTO2 24 slot autochanger. It's been working fairly
well--the most frequent problem being that bacula doesn't use both tape drives
in the autochanger concurrently. However, now bacula has
Linux bacula 2.4.25_pre7-gss-r3 #8 Mo Mär 7 09:53:29 CET 2005 i686 Intel(R)
Pentium(R) 4 CPU 1.80GHz GenuineIntel GNU/Linux
1000 OK: bacula-dir Version: 1.38.9 (02 May 2006)
Hello list,
my problem is that the first "*update slots=8 scan storage=Autoloader" does
not work (the second always does!)
Hi,
On 6/9/2006 2:46 PM, Thomas Sturm wrote:
> Linux bacula 2.4.25_pre7-gss-r3 #8 Mo Mär 7 09:53:29 CET 2005 i686 Intel(R)
> Pentium(R) 4 CPU 1.80GHz GenuineIntel GNU/Linux
> 1000 OK: bacula-dir Version: 1.38.9 (02 May 2006)
>
> Hello list,
> my problem is that the first "*update slots=8 scan sto
ibility to scan
the email and attachments (if any).
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Thomas Sturm
Sent: 09 June 2006 13:47
To: bacula-users@lists.sourceforge.net
Subject: [Bacula-users] update slots fails
Linux bacula 2.4.25_pre7-gss-r3 #8 Mo
Linux bacula 2.4.25_pre7-gss-r3 #8 Mo Mär 7 09:53:29 CET 2005 i686 Intel(R)
Pentium(R) 4 CPU 1.80GHz GenuineIntel GNU/Linux
1000 OK: bacula-dir Version: 1.38.9 (02 May 2006)
Hello list,
my problem is that the first "*update slots=8 scan storage=Autoloader" does
not work (the second always does!)
Can anybody confirm "update slots" is working (regarding ALL drives)
correctly for them in a multidrive autochanger environment? If yes,
could you share your mtx-changer script and bacula-*.conf please?
Thanks,
Sebastian
On 08.03.2006, at 14:45, Sebastian Stark wrote:
On 08.03.2006, at
On 08.03.2006, at 13:49, Dan Langille wrote:
On 8 Mar 2006 at 12:53, Sebastian Stark wrote:
If I use the update slots command in bconsole it asks for a drive
number:
*update slots
Automatically selected Storage: neo4000
Enter autochanger drive[0]:
Regardless what I type here it always tries
On 8 Mar 2006 at 12:53, Sebastian Stark wrote:
> If I use the update slots command in bconsole it asks for a drive
> number:
>
> *update slots
> Automatically selected Storage: neo4000
> Enter autochanger drive[0]:
>
> Regardless what I type here it always tries to unload drive0. How do
> I
If I use the update slots command in bconsole it asks for a drive
number:
*update slots
Automatically selected Storage: neo4000
Enter autochanger drive[0]:
Regardless what I type here it always tries to unload drive0. How do
I get it to unload drive1 as well?
As I read in the archives "u
55 matches
Mail list logo