If the voltage is EXACT when parallel, No problem.
        If one is higher then it feeds the lower voltage alternator
        and may cause a problem, Virg


        On 10/7/2012 9:58 AM, Dene Collett wrote:
> Hi guys
> It has been a while since I posted anything here but I need some advice from
> anybody flying a Revmaster engine equipped with the dual, permanent magnet
> alternators.
> After a few hours of using one of these, I had one of them burn out.
> I have the two alternators supplying their own separate regulators which in
> turn supply their own batteries. I have two master solenoids which can
> select any of the two batteries or both at the same time. When Both
> batteries are selected, the two alternators/regulators are electrically in
> parallel.
> My question is: Is this a problem?
>
> Regards
> Dene Collett
> Avlec Projects cc
> Port Elizabeth
> South Africa
>
>
>
> _______________________________________
> Search the KRnet Archives at http://tugantek.com/archmailv2-kr/search.
> To UNsubscribe from KRnet, send a message to krnet-le...@mylist.net
> please see other KRnet info at http://www.krnet.org/info.html
>

Reply via email to