1. Define 2032 switch. Name it: A1, A1 (FICON switch has two IDs)
2. Define FC switch
3. Connect the CHP to some switch port, i.e. 01, 02
4. Define CU 2107, connect it to another port, i.e. 21, 22
5. Connect CHP to CU adapter. i.e. 01.A121, 02.A122

Your emulated switch is a single point of failure, but I guess you can live with it. :-)

--
Radoslaw Skorupka
Lodz, Poland




W dniu 24.09.2024 o 17:50, Binyamin Dissen pisze:
These are all arbitrary values just to define the setup.

I am open to recommendations.

On Tue, 24 Sep 2024 16:14:34 +0200 Radoslaw Skorupka
<[email protected]> wrote:

:>9033 is (small) ESCON Director.
:>2107 may not support ESCON.
:>What is  CHP type?

--
Binyamin Dissen <[email protected]>
http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to