I dont understand the problem. On the type 30 record, there are the
following fields in the identification section, the location of which can
be found in the header (SMF30IOF, SMF30ILN):

Offset 0, Length 8 - Job Name
Offset 8, Length 8 - Program Name
Offset 16, Length 10 - Step Name
Offset 32, Length 20 - JES JOB ID

Those fields should be able to give you the unique key you seek.

Joe

On Thu, Sep 16, 2021 at 7:44 AM Pierre Fichaud <[email protected]> wrote:

> Martin,
>     Hence my original post.
>     I have 3 "broken" records.
>     I use the type,subtype, date and time in the SMF header to create a
> unique value relating the 3 records.
>     But the time is only in 100ths of seconds.
>     I don't think it's granular enough.
>     Is there something extra I can use to make a unique key?
> Regards, Pierre.
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN