I dont understand the problem. On the type 30 record, there are the following fields in the identification section, the location of which can be found in the header (SMF30IOF, SMF30ILN):
Offset 0, Length 8 - Job Name Offset 8, Length 8 - Program Name Offset 16, Length 10 - Step Name Offset 32, Length 20 - JES JOB ID Those fields should be able to give you the unique key you seek. Joe On Thu, Sep 16, 2021 at 7:44 AM Pierre Fichaud <[email protected]> wrote: > Martin, > Hence my original post. > I have 3 "broken" records. > I use the type,subtype, date and time in the SMF header to create a > unique value relating the 3 records. > But the time is only in 100ths of seconds. > I don't think it's granular enough. > Is there something extra I can use to make a unique key? > Regards, Pierre. > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN