Might you have a hex dump of the "broken" records? What is the physical block length of the file that contains these records and what are you using to read them?

Thanks

Michael

At 11:28 AM 9/14/2021, Pierre Fichaud wrote:

To All,
For SMF types 70-79 (RMF), RMF may create broken records because the volume of data can't fit in 32K.
    So there may be 2 or more "broken" records created.
I have an IBM sample file that has the original unbroken record split into 3 broken records.
    The records are consecutive in the sample file.
But I am getting the records in my SMF exit and I must save the broken records to put them together at a later time. There doesn't seem to be a unique identifier in the product section connecting the 3 records.
    I will use the SMF type/subtype/date/time in the SMF header for now.
    But the time in 100ths of seconds doesn't seem granular enough to me.
    Can someone help me here ?
Thanks in advance, Pierre.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to