If you haven't already, you may want to run the subject through recon-all with the -bigventricles flag since it looks like the lateral ventricle was significantly mislabeled in the aseg. If using the -bigventricles flag doesn't fix your problem, you can edit the aseg.mgz manually by following the directions in this tutorial<https://surfer.nmr.mgh.harvard.edu/fswiki/TkMeditGuide/TkMeditWorkingWithData/FreeviewSegmentations>. Then run the following command (again, substituting <subj_id> for your subject's id):
recon-all -autorecon2-noaseg -autorecon3 -subjid <subj_id> I would try this before doing the wm.mgz edits I suggested in my previous email. Best, Bram ________________________________ From: freesurfer-boun...@nmr.mgh.harvard.edu <freesurfer-boun...@nmr.mgh.harvard.edu> on behalf of Diamond, Bram Ryder <brdiam...@mgh.harvard.edu> Sent: Friday, September 14, 2018 11:07:42 AM To: matthieuvanhou...@gmail.com Cc: freesurfer@nmr.mgh.harvard.edu; astev...@nmr.mgh.harvard.edu Subject: [Freesurfer] Troubles to determine the type of recon editing needed Hi Matthieu, I've taken a look through the files you shared with us and I see the poor surfaces in the posterior right hemisphere you were referring to in your message. It looks like your subject has a combination of abnormally large ventricles and significant wm abnormalities, so I'm surprised FreeSurfer did as well as it did. As for the recon editing - I would recommend editing the wm.mgz to more accurately represent the wm from slice 84 to 39. You can take a look at the white matter edits tutorial<https://surfer.nmr.mgh.harvard.edu/fswiki/FsTutorial/WhiteMatterEditsV6.0> for details on how to do that. Then run the following command (substituting <subj_id> for your subject's id): recon-all -autorecon2-wm -autorecon3 -subjid <subj_id> The surface reconstruction may also benefit from labeling the right lateral ventricle in the wm.mgz (as an intensity of 250) - but I'm not certain since you didn't send us the surfaces for the left hemisphere. Before you do that, edit the wm.mgz as explained in the tutorial and tell us how that goes. All the best, Bram Bram R. Diamond, BSc Research Technician II Laboratory for Computational Neuroimaging Martinos Center for Biomedical Imaging Massachusetts General Hospital 149 13th Street Charlestown, MA 02129 (p): 617-726-6598
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer The information in this e-mail is intended only for the person to whom it is addressed. If you believe this e-mail was sent to you in error and the e-mail contains patient information, please contact the Partners Compliance HelpLine at http://www.partners.org/complianceline . If the e-mail was sent to you in error but does not contain patient information, please contact the sender and properly dispose of the e-mail.