Hi Matthieu

this might be a bug that is fixed in 6.0. Can you cehck the input to 
mri_cc (norm.mgz) and make sure it is not empty? In older versions if the 
skull stripping failed and generated an empty 
norm.mgz/aseg.auto_noCCseg.mgz the mri_cc code would hang.

cheers
Bruce

On Wed, 9 Dec 2015, 
Matthieu Vanhoutte wrote:

> Dear FS epxerts,
> 
> I have launched a recon-all process on a subject. Unfortunately, I tried two 
> times but the process get stucked at the same step
> without error.
> 
> Please found the recon-all.log associated attached to this mail.
> 
> Thanks in advance for helping !
> 
> Best regards,
> Matthieu
> 
>