I am looking for some advice.

(1) In shelex what should I mention to refine occupancy.
I have two molecule in asym unit.
In A molecule residues 89-92 is present, but in B these residues are missing. So I believe in B these residues should not be with zero occupancy, although I donot find any prominent density (Fo-Fc). Occupancy could be anywhere between 0.0 to 1.0. How can I refine this parameter. Or, I should neglect this missing part of residues in B indicating a occupancy of 0.0 or keep a gap of these residues with no information including coordinates.

Right now R1=14% and R1(free) =18%, without making water anisotropic.

(2) I am using 1.4 A data. Should I refine water anisotropically ? If answer is yes, when.

(3) Should I add hydrogen at this resolution. If yes, when should I do.

Thanks
Sam

_________________________________________________________________
The average US Credit Score is 675. The cost to see yours: $0 by Experian. http://www.freecreditreport.com/pm/default.aspx?sc=660600&bcd=EMAILFOOTERAVERAGE

Reply via email to