I understand and wish that enclosure existed but the company that makes that 
particular enclosure will not do a version like you ask.  I would love it if 
there were 2 or 3 entrances in that enclosure.  They make larger ones but that 
is a problem too, they are larger.  Look at our multiple line surge products.  
We put up to 8 surge protectors in the same box.  That is a good box with a 
good seal.  

There is an intermediate size but I don’t think it seals very well.  And of 
course any larger box costs more.  Furthermore they now require minimum 
purchase quantities of 1000 pcs.   That is a gamble in and of itself.   Will 
customers pay say $5 more to have three entrances.  Cost me probably $15K just 
to find out.  

From: Carl Peterson 
Sent: Friday, July 16, 2021 10:49 AM
To: AnimalFarm Microwave Users Group 
Subject: Re: [AFMUG] Cambium Force 300 Ethernet question

We have recently seen similar issues when using Chuck's surge suppressors.  Not 
sure what changed, the RJ 45s, The jack Chuck uses, or my techs but we figured 
out that it was caused by the cable getting pulled sideways in the surge 
enclosure and the tolerance stack on the RJ/RJ jack just not working in our 
favor.  Now we add a zip tie in the little enclosure to force a bend/cross in 
the in/out cable.   

P.S. If you are reading this Chuck we would really really like an enclosure 
with a separate in/out feed similar to the 600SS or something like that so the 
cable can go straight up into the jack and not get pulled sideways.  

On Thu, Jul 15, 2021 at 10:44 PM Nate Burke <n...@blastcomm.com> wrote:

  I've put up alot of the F300, haven't seen any problems.  Bad cable or Radio? 
 Did you try a different POE?  9/10 times Ethernet seems to be a problem with 
the termination and/or cable.  I've done 1000's of ends, but just the other day 
I did one with one blue and green wire switched, I think that caused weird 
Ethernet problems.  Of course it was the end at the radio and not the 
easy-to-get-to inside connection.  


  On 7/15/2021 9:32 PM, Jaime Solorza wrote:

    Installed a PTP  link with great signal but Ethernet port will not lock at 
1000FDX...only 100FDx...if i force it it loses connection or 10mbps hex... 
    Latest firmware...
    Any ideas?
    I even put a Trendnet Ethernet switch between Poe and Edgeswitch...
    Thanks

     



  -- 
  AF mailing list
  AF@af.afmug.com
  http://af.afmug.com/mailman/listinfo/af_af.afmug.com



-- 

Carl Peterson


PORT NETWORKS

401 E Pratt St, Ste 2553

Baltimore, MD 21202

(410) 637-3707 



--------------------------------------------------------------------------------
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to