On Mon, Apr 28, 2025 at 10:33 AM Wade Fife <wade.f...@ettus.com> wrote:
> In practice, you can't have a large number of stream endpoints in a single > USRP, because the crossbar and associated logic adds up. Something on the > order of 16 or so might be a practical limit, depending a lot on what's on > those endpoints. If you need to distinguish between more data streams, then > you'd want to use something like virtual channels or prepending your data > with some kind of identifier. > Thanks for this answer. Does static routing help with this or not particularly? I have only a single configuration I ever want to run, and it's endpoints directly into a modified radio block - no other blocks. Thanks, Brian >
_______________________________________________ USRP-users mailing list -- usrp-users@lists.ettus.com To unsubscribe send an email to usrp-users-le...@lists.ettus.com