Hi Mark,

b2xx_fx3_utils --init-device is your friend. After you run that, you can
run `usrp_burn_mb_eeprom` again to configure serial number etc.

--M

On Thu, Jun 27, 2024 at 8:45 PM Mark Rosenbaum <m_ro...@mit.edu> wrote:

> Hi All,
> I was recently working on fixing an issue with my B210 and accidentally
> re-flashed the bootloader. In the process it seems to have fully wiped the
> EEPROM and now when attempting to perform any action on the device I get
> the following error:
> "Error: RuntimeError: B200 unknown product code: 0xe3e0".
> Is there any way to go back and re-flash the original values?  I've tried
> to use the usrp_burn_mb_eeprom command with the recover_mb_eeprom but it
> still fails with the same error.
> Thanks,
> Mark
> _______________________________________________
> USRP-users mailing list -- usrp-users@lists.ettus.com
> To unsubscribe send an email to usrp-users-le...@lists.ettus.com
>
_______________________________________________
USRP-users mailing list -- usrp-users@lists.ettus.com
To unsubscribe send an email to usrp-users-le...@lists.ettus.com

Reply via email to