Yes, you are right!

1\. This should not support 4 10GbE, when I use CG 400 image, the ubuntu20 can 
automatically recognize it as 100 GbE 

2\. But there is a new problem: in gnuradio I can't change the sample rate, 
x410 devices always use a sample rate of 491.520 MHz, resulting in the computer 
can not output complete data to x410 devices in time. 

Erro like this:

**\[INFO\] \[MPM.PeriphManager\] init() called with device args 
\`fpga=CG_400,mgmt_addr=192.168.10.2,name=ni-x4xx-324AA5D,product=x410,clock_source=internal,time_source=internal'.**

**usrp_source :warning: Requested sample rate 4.9152e+06 Hz not set; instead, 
4.9152e+08 Hz used.**

**\[WARNING\] \[0/Radio#1\] Requesting invalid sampling rate from device: 
4.9152 MHz. Actual rate is: 491.52 MHz.**

**\[WARNING\] \[MULTI_USRP\] Could not set RX rate to 4.915 MHz. Actual rate is 
491.520 MHz**

**\[WARNING\] \[0/Radio#0\] Requesting invalid sampling rate from device: 
4.9152 MHz. Actual rate is: 491.52 MHz.**

**\[WARNING\] \[MULTI_USRP\] Could not set TX rate to 4.915 MHz. Actual rate is 
491.520 MHz**

So I wondered how to change the sample rate of the device under the CG 400 
image?

Any insights would be greatly appreciated:)