I also happen to have some spare B200 devices around and I can confirm
what @Martin stated.
Since we are working in a jitter-sensitive critical application and after
the tests I've perfomed, I'm inclined to think the minimum jitter scenario
occurs when using the internal reference (2 ppm), given that even using a
high precision laboratory equipment (Agilent) as an external clock source
shows worse results than the former (as it can be seen in the images from
my first post). Shall we work with the internal reference then or am I
missing something on what you said?

Regards,
Brais.
_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

Reply via email to