On 08/07/2018 11:49 AM, Muhammad Aslam (UGent-imec) via USRP-users wrote:
Dear(s),
I am from Ghent university and currently, we are using USRP X310. We
would like to operate it in TDD mode for our specific application.
Since our application is very sensitive to latency and the Switching
time (Tx to Rx or vice versa) of USRP X310 RF front-end in TDD
operation can be foreseen a major addition in overall latency, Can I
learn the following values:
* Tx to Rx switching time (in us) of USRP X310 RF front-end,
* Rx to Tx switching time of (in us) USRP X310 RF front-end.
Furthermore, could you please tell the procedure or example that can
be used to measure these switching times?
Kind regards
--
Muhammad Aslam
PhD student at IDLab
Ghent University - imec
iGent Tower - Department of Information Technology
Technologiepark-Zwijnaarde 15, B-9052 Ghent, Belgium
W:*www.muhamedaslam.wordpress.com*
W: www.IDLab.ugent.be
You haven't mentioned which daughter-cards you are using, which is very
important in characterizing this property.
_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com