The same solution that works for E310 won't work for X310. The easiest fix
will be to use a DDC block to reduce the sample rate ahead of the Split
Stream block. The RFNoC bus cannot handle two full-rate streams on a single
NoC port.

Nick

On Thu, Jun 7, 2018, 2:44 AM Juan Francisco via USRP-users <
usrp-users@lists.ettus.com> wrote:

> Unfortunately I don't have a fix for this, but I have seen similar
> behavior.  I have only been able to get the SplitStream block on the first
> run after an FPGA reconfiguration (or X310 power cycle).  If you try
> running the flowgraph a second time, it hangs and nothing gets through the
> SplitStream.
>
> On Wed, Jun 6, 2018 at 7:05 PM, Peter Sanchez via USRP-users <
> usrp-users@lists.ettus.com> wrote:
>
>> Hi All,
>>
>> I have a RFNoC Receiver --> Split stream --> x2 DDC blocks on the X310.
>> I see a ton of overrun on chan 0 errors after adding the Split Stream
>> block and GNU Radio Companion eventually crashes all together.
>>
>>
>> I read about a similar problem on the E310 and the fix was to change the
>> ce_clk to bus_clk in the rfnoc_ce_auto_inst (
>> http://lists.ettus.com/pipermail/usrp-users_lists.ettus.com/2017-February/023539.html
>> ).
>> I tried changing that in the rfnoc_ce_auto_inst_x310.v code and reflashed
>> the FPGA but this didn't change the overrun errors.
>>
>> Any thoughts?
>> Thanks!
>>
>> _______________________________________________
>> USRP-users mailing list
>> USRP-users@lists.ettus.com
>> http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com
>>
>>
> _______________________________________________
> USRP-users mailing list
> USRP-users@lists.ettus.com
> http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com
>
_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com