W dniu 09.10.2017 o 09:36, Piotr Krysik via USRP-users pisze:
> One thing that helped was replacing one of the USRP B210 in the pair
> with another one.
Hi,

I checked everything again and I found out that after replacing one of
my 10MHz ref SMA cable the phase difference between any devices behaves
much better. It seems that one of the cables was faulty. So... mea culpa
guys (for the first time with B210 ;) ). Many thanks for your time, you
are always very helpful.

Best Regards,
Piotr Krysik


_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

Reply via email to