Hello Michal,

Am 16.02.2016 um 13:12 schrieb Michal Simek:
Hi Stephen,

trying to run the latest testing on zynq board and getting this
main_signon error.

This is what I am running
./test/py/test.py --bd zynq_zc702  --build --board-identity zc702
and getting below.

Does this board has SPL support without SPL serial output?

If so, can you try my patch:
http://patchwork.ozlabs.org/patch/583348/

Thanks!

bye,
Heiko

Thanks,
Michal

U-Boot 2016.03-rc2 (Feb 16 2016 - 13:10:03 +0100)

Model: Zynq ZC702 Development Board
Board: Xilinx Zynq
I2C:   ready
DRAM:  ECC disabled 1 GiB

Bad pattern found on console: main_signon

FAILED:
request = <SubRequest 'u_boot_console' for <Function 'test_version'>>

     @pytest.fixture(scope='function')
     def u_boot_console(request):
         """Generate the value of a test's u_boot_console fixture.

         Args:
             request: The pytest request.

         Returns:
             The fixture value.
         """

       console.ensure_spawned()

test/py/conftest.py:311:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _

self = <u_boot_console_exec_attach.ConsoleExecAttach object at
0x7f2b33dee8d0>

     def ensure_spawned(self):
         """Ensure a connection to a correctly running U-Boot instance.

             This may require spawning a new Sandbox process or resetting
target
             hardware, as defined by the implementation sub-class.

             This is an internal function and should not be called directly.

             Args:
                 None.

             Returns:
                 Nothing.
             """

         if self.p:
             return
         try:
             self.log.start_section('Starting U-Boot')
             self.at_prompt = False
             self.p = self.get_spawn()
             # Real targets can take a long time to scroll large amounts of
             # text if LCD is enabled. This value may need tweaking in the
             # future, possibly per-test to be optimal. This works for 'help'
             # on board 'seaboard'.
             if not self.config.gdbserver:
                 self.p.timeout = 30000
             self.p.logfile_read = self.logstream
             if self.config.buildconfig.get('config_spl', False) == 'y':
                 m = self.p.expect([pattern_u_boot_spl_signon] +
self.bad_patterns)
                 if m != 0:
                     raise Exception('Bad pattern found on console: ' +
                                   self.bad_pattern_ids[m - 1])
E                                   Exception: Bad pattern found on
console: main_signon

test/py/u_boot_console_base.py:310: Exception

_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot


--
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot

Reply via email to