Thanks Stefano, On 10/06/2014 08:42 AM, Stefano Babic wrote: > Hi Eric, > > On 02/10/2014 21:16, Eric Nelson wrote: >> Several customers are using UART2 (normally the serial console >> for U-Boot) as connections to printers or other peripherals >> that are not tolerant of stray inputs during reset. >> >> Provide a simple way to eliminate output on the serial port >> by conditionally configuring these pads as GPIOs during >> U-Boot. >> >> Signed-off-by: Eric Nelson <eric.nel...@boundarydevices.com> >> --- >> board/boundary/nitrogen6x/nitrogen6x.c | 6 ++++++ >> 1 file changed, 6 insertions(+) >> >> diff --git a/board/boundary/nitrogen6x/nitrogen6x.c >> b/board/boundary/nitrogen6x/nitrogen6x.c >> index e795492..621cdbc 100644 >> --- a/board/boundary/nitrogen6x/nitrogen6x.c >> +++ b/board/boundary/nitrogen6x/nitrogen6x.c >> @@ -77,9 +77,15 @@ static iomux_v3_cfg_t const uart1_pads[] = { >> MX6_PAD_SD3_DAT7__UART1_TX_DATA | MUX_PAD_CTRL(UART_PAD_CTRL), >> }; >> >> +/* #define CONFIG_SILENT_UART */ > > Theoretically, we have already in U-Boot CONFIG_SILENT_CONSOLE, without > the need to introduce a new CONFIG_. > >> static iomux_v3_cfg_t const uart2_pads[] = { >> +#ifndef CONFIG_SILENT_UART >> MX6_PAD_EIM_D26__UART2_TX_DATA | MUX_PAD_CTRL(UART_PAD_CTRL), >> MX6_PAD_EIM_D27__UART2_RX_DATA | MUX_PAD_CTRL(UART_PAD_CTRL), >> +#else >> + MX6_PAD_EIM_D26__GPIO3_IO26 | MUX_PAD_CTRL(UART_PAD_CTRL), >> + MX6_PAD_EIM_D27__GPIO3_IO27 | MUX_PAD_CTRL(UART_PAD_CTRL), >> +#endif > > I understand the reason, anyway this looks like a hack (uart is still > configured while iomux is not correctly set). Can you check if your goal > is simply reached with CONFIG_SILENT_CONSOLE ? > Will do. I wasn't aware of that one.
Regards, Eric _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot