Please find attached the output from smartctl -a from a (failing) Samsung HD103SI, which does not appear to be in your database (as at version 5.39.1)

Regards,
Keith
smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     SAMSUNG HD103SI
Serial Number:    S1VSJ9AS716647
Firmware Version: 1AG01118
User Capacity:    1,000,204,886,016 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 3b
Local Time is:    Thu Oct  7 10:46:27 2010 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 114) The previous self-test completed having
                                        the read element of the test failed.
Total time to complete Offline 
data collection:                 (12725) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 213) minutes.
Conveyance self-test routine
recommended polling time:        (  23) minutes.
SCT capabilities:              (0x003f) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   099   096   051    Pre-fail  Always       
-       3387
  3 Spin_Up_Time            0x0007   081   081   011    Pre-fail  Always       
-       6590
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       306
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   100   100   051    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0025   100   100   015    Pre-fail  Offline      
-       10916
  9 Power_On_Hours          0x0032   099   099   000    Old_age   Always       
-       6846
 10 Spin_Retry_Count        0x0033   100   100   051    Pre-fail  Always       
-       0
 11 Calibration_Retry_Count 0x0012   100   100   000    Old_age   Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       305
 13 Read_Soft_Error_Rate    0x000e   099   096   000    Old_age   Always       
-       3386
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       
-       0
184 End-to-End_Error        0x0033   100   100   000    Pre-fail  Always       
-       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       8955
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0022   083   060   000    Old_age   Always       
-       17 (Lifetime Min/Max 12/17)
194 Temperature_Celsius     0x0022   082   057   000    Old_age   Always       
-       18 (Lifetime Min/Max 12/20)
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       
-       2658821
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0012   089   089   000    Old_age   Always       
-       450
198 Offline_Uncorrectable   0x0030   100   100   000    Old_age   Offline      
-       1
199 UDMA_CRC_Error_Count    0x003e   100   100   000    Old_age   Always       
-       4
200 Multi_Zone_Error_Rate   0x000a   100   100   000    Old_age   Always       
-       0
201 Soft_Read_Error_Rate    0x000a   253   253   000    Old_age   Always       
-       0

SMART Error Log Version: 1
ATA Error Count: 4
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 4 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  00 50 04 0b 00 00 a0   at LBA = 0x0000000b = 11

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  21 00 04 0b 00 00 a0 00      02:42:32.310  READ SECTOR(S) [OBS-5]
  00 00 01 01 00 00 a0 ff      02:42:32.010  NOP [Abort queued commands]
  00 00 01 01 00 00 a0 ff      02:42:21.970  NOP [Abort queued commands]
  ec 00 04 00 00 00 a0 02      02:41:47.050  IDENTIFY DEVICE
  00 00 01 01 00 00 a0 ff      02:41:46.670  NOP [Abort queued commands]

Error 3 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  00 50 04 0b 00 00 a0   at LBA = 0x0000000b = 11

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  21 00 04 0b 00 00 a0 00      00:06:22.090  READ SECTOR(S) [OBS-5]
  ee 41 9d 3b 3e ce 43 00      00:06:22.000  IDENTIFY DEVICE DMA [OBS-4]
  00 00 01 01 00 00 a0 ff      00:06:21.700  NOP [Abort queued commands]
  00 00 01 01 00 00 a0 ff      00:05:46.400  NOP [Abort queued commands]

Error 2 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 53 33 11 00 00 e0  Error: ICRC, ABRT 51 sectors at LBA = 0x00000011 = 17

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 44 00 00 00 e0 00      00:04:46.570  READ DMA
  c8 00 08 bf 00 22 e7 00      00:03:42.350  READ DMA
  c8 00 08 bf e0 5f e7 00      00:03:25.010  READ DMA
  c8 00 08 bf 00 5e e7 00      00:03:25.000  READ DMA
  c8 00 08 bf e0 71 e7 00      00:03:23.210  READ DMA

Error 1 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  When the command that caused the error occurred, the device was active or 
idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  00 d0 00 00 00 00 a0   at LBA = 0x00000000 = 0

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ca 00 6b 9c 1c a0 e0 00      00:12:55.020  WRITE DMA
  ca 00 01 b6 e5 40 e1 00      00:12:55.020  WRITE DMA
  c8 00 08 4f e1 82 e1 00      00:12:55.020  READ DMA
  c8 00 08 07 e1 82 e1 00      00:12:55.000  READ DMA
  ea 00 00 46 8a a1 a0 00      00:12:54.970  FLUSH CACHE EXT

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed: read failure       20%      6846         
1358010876
# 2  Short offline       Completed: read failure       20%      6837         
1358010876
# 3  Short offline       Completed: read failure       20%      6820         
1358010876
# 4  Short offline       Completed: read failure       20%      6804         
1358010876
# 5  Short offline       Completed: read failure       20%      6782         
1358010876
# 6  Short offline       Completed: read failure       20%      6780         
1358010876
# 7  Extended offline    Completed without error       00%      6772         -
# 8  Short offline       Completed without error       00%      6766         -
# 9  Short offline       Completed without error       00%      6745         -
#10  Short offline       Completed without error       00%      6721         -
#11  Short offline       Completed without error       00%      6704         -
#12  Short offline       Completed without error       00%      6689         -
#13  Extended offline    Completed without error       00%      6677         -
#14  Short offline       Completed without error       00%      6671         -
#15  Short offline       Completed: read failure       20%      6669         
1193483063
#16  Short offline       Completed: read failure       20%      6668         
1193483063
#17  Short offline       Completed: read failure       20%      6665         
1193483582
#18  Extended offline    Completed: read failure       30%      6661         
1193482933
#19  Short offline       Completed without error       00%      6641         -
#20  Extended offline    Completed: read failure       30%      6621         
1193482933
#21  Short offline       Completed without error       00%      6617         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Beautiful is writing same markup. Internet Explorer 9 supports
standards for HTML5, CSS3, SVG 1.1,  ECMAScript5, and DOM L2 & L3.
Spend less time writing and  rewriting code and more time creating great
experiences on the web. Be a part of the beta today.
http://p.sf.net/sfu/beautyoftheweb
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to