Please find attached the output from smartctl -a from a Maxtor STM380815AS, which does not appear to be in your database (as at version 5.39.1)

Regards,
Keith
smartctl 5.39.1 2010-01-28 r3054 [x86_64-unknown-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     MAXTOR STM380815AS
Serial Number:    6QZ4Y1B1
Firmware Version: 3.AAD
User Capacity:    80,026,361,856 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Thu Oct  7 10:40:59 2010 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      ( 249) Self-test routine in progress...
                                        90% of test remaining.
Total time to complete Offline 
data collection:                 ( 430) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  27) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   118   099   006    Pre-fail  Always       
-       199235914
  3 Spin_Up_Time            0x0003   097   097   000    Pre-fail  Always       
-       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       
-       462
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000f   074   060   030    Pre-fail  Always       
-       27369625
  9 Power_On_Hours          0x0032   098   098   000    Old_age   Always       
-       1788
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       
-       462
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       
-       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0022   071   055   045    Old_age   Always       
-       29 (Lifetime Min/Max 21/30)
194 Temperature_Celsius     0x0022   029   045   000    Old_age   Always       
-       29 (0 18 0 0)
195 Hardware_ECC_Recovered  0x001a   088   072   000    Old_age   Always       
-       242798096
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x003e   200   162   000    Old_age   Always       
-       7596
200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline      
-       0
202 Data_Address_Mark_Errs  0x0032   100   253   000    Old_age   Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      1780         -
# 2  Short offline       Completed without error       00%      1763         -
# 3  Short offline       Completed without error       00%      1748         -
# 4  Short offline       Completed without error       00%      1724         -
# 5  Extended offline    Completed without error       00%      1718         -
# 6  Short offline       Completed without error       00%      1709         -
# 7  Short offline       Completed without error       00%      1688         -
# 8  Short offline       Completed without error       00%      1664         -
# 9  Short offline       Completed without error       00%      1648         -
#10  Short offline       Completed without error       00%      1632         -
#11  Short offline       Completed without error       00%      1608         -
#12  Short offline       Completed without error       00%      1584         -
#13  Extended offline    Aborted by host               70%      1565         -
#14  Short offline       Completed without error       00%      1560         -
#15  Short offline       Completed without error       00%      1536         -
#16  Short offline       Completed without error       00%      1523         -
#17  Short offline       Completed without error       00%      1508         -
#18  Short offline       Completed without error       00%      1493         -
#19  Short offline       Completed without error       00%      1476         -
#20  Short offline       Completed without error       00%      1463         -
#21  Short offline       Self-test routine in progress 90%      1788         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Beautiful is writing same markup. Internet Explorer 9 supports
standards for HTML5, CSS3, SVG 1.1,  ECMAScript5, and DOM L2 & L3.
Spend less time writing and  rewriting code and more time creating great
experiences on the web. Be a part of the beta today.
http://p.sf.net/sfu/beautyoftheweb
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to