uestions on these and other topics!
With best regards,
Martijn Fransen
Director of Structural Analysis
Malvern Panalytical
-Original Message-
From: rietveld_l-requ...@ill.fr [mailto:rietveld_l-requ...@ill.fr] On Behalf Of
Daniel Chateigner
Sent: Thursday, February 01, 2018 3:18
Hello Frantisek,
I am sorry to hear about this inconvenience.
Our HighScore team will look into this as soon as possible and help you to get
going again.
With best regards, Martijn
Martijn Fransen, PhD
Director of Structural Analysis
[cid:image001.png@01D4785C.2F85F6E0]
Direct
Mob
+31 546
Hello Andreas,
When I met Jim Cline at the Denver Conference
he spoke about a fluid to drop into a (possibly backloaded) powder sample
in order to make it solid. I will not put Jim's e-mail address on the Rietveld
list but am quite sure he is subscribed - Jim, could you advise?
With best regard
Dear Natale,
I think you are seeing two effects instead
of one.
First of all, you will indeed see Co
fluorescence. Cu K-Alpha1 is able to excite Co fluorescence very efficiently,
as mentioned already by Jens.
The choice of optics and radiation with
this type of samples can be tricky when you
Dear Rietvelders,
in addition to Nita Dragoe's remark:
please note that the description of the XRDML file (the "schema")
can be found on the website http://www.xrdml.com; it can be used freely
by any software developer. With this file format, we tried to get rid of
all the issues Nita referred t
Dear Santosh,
absolutely, the product has a large user
base. But let us continue that discussion off-list.
With best regards,
Martijn
Dr. Martijn J. Fransen
Product Manager XRD
PANalytical
Lelyweg 1
7602 EA Almelo, The Netherlands
Phone ++31 546 534 345
Fax ++ 31 546 534 598
PANalytica
Dear Rietvelders,
Thanks to a steadily growing business,
we are looking for an additional XRD specialist in our European Application
Laboratory in Almelo, The Netherlands. Please find a detailed description
of the function and the requirements below.
Application Specialist XRD
Dear Rietvelders,
Unfortunately my first mail contained text
that was not readable for everybody. Therefore, I am resending this mail
as a plain text message.
Dear Congwu,
Maybe your Mo K-Alpha contribution gets a lot of stronger if you would
range the kV settings of your X-ray generator. As a rule of thumb, you
need an acceleration voltage that is about 4 x higher than the
characteristic energy in keV. In other words, I would advise to run your
so
Dear Rietveld list members,
with this mail I want to draw your attention for a job opportunity at
PANalytical.
With best regards,
Martijn Fransen
Job Opportunity:
APPLICATION SPECIALIST X-RAY DIFFRACTION
Description:
We search for a dynamic and internationally oriented regional
Dear Rietvelders,
As an addition to the remarks made already, I would like to mention a few
other cases where variable slits can be useful:
- when performing diffraction measurements at elevated temperatures using
non-ambient chambers with heating strips: the use of a constant irradiated
area
Dear Leonid,
are you telling us that you discovered a new element? ;-)
Best regards,
Martijn Fransen - Senior Product Manager XRD
PANalytical
Lelyweg 1
7602 EA Almelo
The Netherlands
T +31 546 534345
F +31 546 534 598
martijn.fran...@panalytical.com
www.PANalytical.com
contact Mr. Huub Smit, manager Application Competence Center, +31
(0)546 534 416.
Procedure:
Please send your applications to Mr. Cees van Gilst, Human Resource
Director.
cees.van.gi...@panalytical.com
---
Martijn Fransen - Product Marketing
13 matches
Mail list logo