External Email - Use Caution
Hi Yujing,
Thank you very much for clarifying and letting me know of your testing results. I really appreciate all
your help with this issue.
Andrew
*Andrew Beaudin, PhD* | Research Associate
University of Calgary | Cumming School of
matrix, maybe very subtle shearing as the determinant is still
very close to 1, so no scaling). This could be a numerical issue. Anyway
increasing the threshold to 0.001 should fix this. Or did you get another error
after that for this specific case?”
Thanks again.
Andrew
Andrew Beaudin, PhD
External Email - Use Caution
Hi Yujing,
No problem at all. I really appreciate yours, and now Martin's, help with this issue. If you would like to
start with dicoms, please let me know.
Again, thank you both for your help.
Andrew
----
*Andrew Beaudin, PhD* | Res
6.0 - same MyMatrix::RotationMean Error.
Again, thank you for the help….and please let me know if your need any
additional information or anything clarified.
Andrew
----
Andrew Beaudin, PhD | Postdoctoral Scholar
University of Calgary | Cumming School of Medicine
Department of Clinical Neuroscien
z24_TzO25_ti0wPS3jRLw/https%3A%2F%2Fwww.mail-archive.com%2Ffreesurfer%40nmr.mgh.harvard.edu%2Fmsg72948.html)
but I still cannot find a solution to this problem.
Any insights are greatly appreciated.
Thanks for the help.
Andrew
Andrew Beaudin, PhD | Postdoctoral Scholar
University of Calgar
.
Interestingly, while including the -affine flag works for some participants,
for others I get "MatrixLog Error: Result too imaginary to ignore!" error.
Any help/recommendations are greatly appreciated.
Thanks
Andrew
----
Andrew Beaudin, PhD | Research Associate
University of Calgary
c3Nsfek1dX-2ZcfyofJgATm7_3x4dxBVVFXtW3LjQdkXeF5FP0UwRptADFLkDJRHCnLZ0xT8KDhGNfGNJeAsoOkOn_5HQg--PcUyUeQ6bMZMgly3L22SbfL48bjyIQb1ZIEXiJr0S0TEKN5X2H3JHlXqDYXQgNPTsnGyVX4iQl65pbf6ChI/https%3A%2F%2Fsiliconheaven.info%2Fxlaunch-configuration-file%2F%23gsc.tab%3D0) for the steps.
Hope this helps.
Andrew
----
*Andrew Beaudin, PhD* | Postdoctoral Scholar
University of Calgary
| awk
'{print $2; exit;}'):0.0
Remember, when you modify the Xming configuration file through
XLaunch, make sure that Xming is not running or the updated config
file will not be saved.
Hope this helps.
Andrew
Andrew Beaudin, PhD |
fer to use the rigid body
registration but am at a loss for why these images are failing using the rigid
body registration is failing. Any help/insights/recommendations are greatly
appreciated.
Thank you very much.
Andrew
Andrew Beaudin, PhD | Postdoctoral Scholar
University of Calgary | C
why these
images are failing using the rigid body registration is failing. Any
help/insights/recommendations are greatly appreciated.
Thank you very much.
Andrew
Andrew Beaudin, PhD | Postdoctoral Scholar
University of Calgary | Cumming School of M
iated.
Thank you very much.
Andrew
Andrew Beaudin, PhD | Postdoctoral
Scholar
University of Calgary | Cumming School of Medicine
Department of Clinical Neurosciences
HSC Rm 2935J, 3330 Hospital Drive N.W. | Calgary, AB | T2
11 matches
Mail list logo