Re: [Bacula-users] job canceled - block.c:318 Volume data error at 0:0!

2013-07-23 Thread John Drescher
>> 23-Jul 01:03 fg-back-sd JobId 7894: 3305 Autochanger "load slot 7, drive >> 0", status is OK. >> 23-Jul 01:04 fg-back-sd JobId 7894: Error: >> /home/kern/bacula/k/bacula/src/stored/block.c:318 Volume data error at >> 0:0! >> Block checksum mismatch in block=0 len=200: calc=4b2b65bc blk=2c508db9

Re: [Bacula-users] job canceled - block.c:318 Volume data error at 0:0!

2013-07-23 Thread Radosław Korzeniewski
Hello, 2013/7/23 Markus Rosjat > HEy there, > > I have a problem with a scheduled job that I run, the requested Tape > is in the loader and gets mounted but I get a Volume Data Error and > Bacula tells me to mount the Tape or label a new one. Im pretty lost > with that behaviour, I canceled th

[Bacula-users] job canceled - block.c:318 Volume data error at 0:0!

2013-07-22 Thread Markus Rosjat
HEy there, I have a problem with a scheduled job that I run, the requested Tape is in the loader and gets mounted but I get a Volume Data Error and Bacula tells me to mount the Tape or label a new one. Im pretty lost with that behaviour, I canceled the job and checked what status the tape ha