>> 23-Jul 01:03 fg-back-sd JobId 7894: 3305 Autochanger "load slot 7, drive >> 0", status is OK. >> 23-Jul 01:04 fg-back-sd JobId 7894: Error: >> /home/kern/bacula/k/bacula/src/stored/block.c:318 Volume data error at >> 0:0! >> Block checksum mismatch in block=0 len=200: calc=4b2b65bc blk=2c508db9 > > > This a main problem. Your volume is corrupted. > In my opinion you should erase (with deleting it from catalog) a tape and > label it again. If problem will still exist dispose a tape and get a new > one. >
Also make sure you are using a non rewinding device for your tape drives if possible. Although even with that I have had a few error tapes on unexpected power cycles. One example was the UPS battery died on the SD machine (the director and db are on different servers) which sits in a network closet that I rarely go into. John ------------------------------------------------------------------------------ See everything from the browser to the database with AppDynamics Get end-to-end visibility with application monitoring from AppDynamics Isolate bottlenecks and diagnose root cause in seconds. Start your free trial of AppDynamics Pro today! http://pubads.g.doubleclick.net/gampad/clk?id=48808831&iu=/4140/ostg.clktrk _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users