Re: [Bacula-users] Tape library problem

2022-01-11 Thread Jose Alberto
This error also occurs, when you have a tape library with n + 1 Drive, but in the SD you only declare the 2nd or 3rd and not the main one. Apparently for Bacula, the library needs to always have the Drive that it considers main declared, usually Index 0. On Tue, Jan 11, 2022 at 12:14 PM Tomasz Św

Re: [Bacula-users] Tape library problem

2022-01-11 Thread Tomasz Świderski
I find config error, in bacula-dir.conf is Media Type = LTO-8, in  bacula-sd.conf is Media Type = LTO8 Thanks W dniu 2022-01-11 o 16:27, Heitor Faria pisze: The baculi documentation discourages the use of LabelMedia = yes with libraries https://www.bacula.org/11.0.x-manuals/en/ma

Re: [Bacula-users] Tape library problem

2022-01-11 Thread Heitor Faria
> The baculi documentation discourages the use of LabelMedia = yes with > libraries > [ https://www.bacula.org/11.0.x-manuals/en/main/Basic_Volume_Management.html | > https://www.bacula.org/11.0.x-manuals/en/main/Basic_Volume_Management.html ] And I never undestood why... Rgds. -- MSc Heito

Re: [Bacula-users] Tape library problem

2022-01-11 Thread Tomasz Świderski
The baculi documentation discourages the use of LabelMedia = yes with libraries https://www.bacula.org/11.0.x-manuals/en/main/Basic_Volume_Management.html W dniu 2022-01-11 o 15:59, Pedro Oliveira pisze: Hi Tomasz, Please could you change the following option on your device in your BEE Stor

Re: [Bacula-users] Tape library problem

2022-01-11 Thread Tomasz Świderski
Unfortunately, the error is the same W dniu 2022-01-11 o 15:59, Pedro Oliveira pisze: Hi Tomasz, Please could you change the following option on your device in your BEE Storage Daemon Server Configuration file The second change that is necessary to make automatic labeling work is to give t

[Bacula-users] Tape library problem

2022-01-11 Thread Tomasz Świderski
Set up a library of tapes in Bacula. I have a problem when I want to label in bconsole. * label barcode 3306 Issuing autochanger "slots" command. Device "LibraryHP0" has 8 slots. 3306 Issuing autochanger "list" command. The following Volumes will be labeled: Volume slot ==    1 270011