Set up a library of tapes in Bacula. I have a problem when I want to label in bconsole.
* label barcode
3306 Issuing autochanger "slots" command.
Device "LibraryHP0" has 8 slots.
3306 Issuing autochanger "list" command.
The following Volumes will be labeled:
Volume slot
==============
   1 270011L8
   2 270012L8
   3 .........
Sending label command for Volume "270011L8" Slot 1 ...
3999 Device "LibraryHP0" not found or could not be opened.
Label command failed for Volume 270011L8.

I've done the tests recommended in the documentation before (mtx-changer, mt). They all work. In bconsole, I can properly execute commands on the library: update slots, mount, un mount, status slots. Unfortunately, the label and label barcode ends with an error as mentioned above.
My configuration snippets:

The library and bacula-sd is installed on a different host than bacula-dir

bacula-sd.conf

Autochanger {
  Name = LibraryHP0
  Device = Drive0
  Changer Device = /dev/sg5
  Changer Command = "/opt/bacula/scripts/mtx-changer %c %o %S %a %d"
}

Device {
  Name = Drive0
  Media Type = LTO8
  Drive Index = 0
  Archive Device = /dev/nst0    # Normal archive device
  Autochanger = yes
  LabelMedia = no
  RandomAccess = no
  AutomaticMount = yes
  AlwaysOpen = yes
  RemovableMedia = yes
  Maximum Changer Wait = 600
  Maximum Rewind Wait = 600
  Maximum Open Wait = 600
  Maximum Concurrent Jobs = 2
}

bacula-dir.conf

Autochanger {
  Name = k-bacula3-sd-LibraryHP
  Address = 192.168.1.100
  SDPort = 9103
  Password = "xxxxxxxxxxxxxxxxxxxx"
  Device = LibraryHP0
  Media Type = LTO-8
  Maximum Concurrent Jobs = 10
  Autochanger = k-bacula3-sd-LibraryHP
}


_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to