Re: [Bacula-users] no catalaog files

2012-05-21 Thread Andre Lorenz
On 21.05.2012 16:00, John Drescher wrote: > On Mon, May 21, 2012 at 8:21 AM, Andre Lorenz wrote: >> Hello, >> >> after upgrading my bacula to 5.2.6 i can't read anymore my catalog files. >> >> my installation was and is based on a mysql-setup. >> >

[Bacula-users] no catalaog files

2012-05-21 Thread Andre Lorenz
Hello, after upgrading my bacula to 5.2.6 i can't read anymore my catalog files. my installation was and is based on a mysql-setup. if i do show catalogs i'm getting: Catalog: name=MyCatalog address=*None* DBport=0 db_name=bacula db_driver=*None* db_user=bacula MutliDBConn=0 my bacula_con

Re: [Bacula-users] Full-Job gets killed by time limit

2011-08-31 Thread Andre Lorenz
On 31.08.2011 14:53, Uwe Bolick wrote: > Hi, > > I have to backup a remote site with several TB of data over a "slow" > connection (varying between 10-15 GB per hour). Under these > circumstances, one of my initial "Full" jobs gets killed after 6 days: > >> 30-Aug 21:48 gothmog-dir JobId 34535: Fat

[Bacula-users] bacula windows2008 Server and exchange2007

2011-08-01 Thread Andre Lorenz
Hello together, i am looking for a good howto / best practice for backup and recovery of exchange2007 server. i have following constellation: bacula-server:linux-debian 64 bit Windows2008 (64bit) with exchange 2007. thanks for help in advance. Andre

Re: [Bacula-users] restore of old files

2011-06-23 Thread Andre Lorenz
M, Andre Lorenz wrote: > >> On 22.06.2011 13:22, Jeremy Maes wrote: >>> Op 22/06/2011 12:40, Andre Lorenz schreef: >>>> hi, >>>> >>>> i'd like to restore old files, but the files are not shown up :-( > What do you mean by this? You do a rest

Re: [Bacula-users] restore of old files

2011-06-22 Thread Andre Lorenz
On 22.06.2011 13:22, Jeremy Maes wrote: > Op 22/06/2011 12:40, Andre Lorenz schreef: >> hi, >> >> i'd like to restore old files, but the files are not shown up :-( >> >> i can see the old backup job, but if i would like to select this job, >> the

[Bacula-users] restore of old files

2011-06-22 Thread Andre Lorenz
hi, i'd like to restore old files, but the files are not shown up :-( i can see the old backup job, but if i would like to select this job, there are no files shown up for this. the retention period for this job is 1 year, also the media will be kept for 1 year. does i have to inventory the medi

Re: [Bacula-users] update slots scan

2011-05-27 Thread Andre Lorenz
On 27.05.2011 14:03, John Drescher wrote: > On Fri, May 27, 2011 at 7:51 AM, Andre Lorenz wrote: >> On 27.05.2011 09:41, Mauro Colorio wrote: >>> what's the result of tapeinfo -f /dev/sg6 ? >>> >>> ciao >>> Mauro >> i changed

Re: [Bacula-users] update slots scan

2011-05-27 Thread Andre Lorenz
MOVE MEDIUM from Element Address 257 to 11 Failed On 27.05.2011 13:51, Andre Lorenz wrote: > On 27.05.2011 09:41, Mauro Colorio wrote: >> what's the result of tapeinfo -f /dev/sg6 ? >> >> ciao >> Mauro > i changed something ;-) > reconfigured some stuff but noc

Re: [Bacula-users] update slots scan

2011-05-27 Thread Andre Lorenz
On 27.05.2011 09:41, Mauro Colorio wrote: > what's the result of tapeinfo -f /dev/sg6 ? > > ciao > Mauro i changed something ;-) reconfigured some stuff but noc change :-( lsscsi -g ... [1:0:0:0]mediumx NEC LL0101H-0A 0002 /dev/sch0 /dev/sg2 [1:0:1:0]tapeIBM ULTRIUM-

Re: [Bacula-users] update slots scan

2011-05-26 Thread Andre Lorenz
Hi, i just got it back half working :-( dmesg | grep 2:0:1:1 [ 79.677949] scsi 2:0:1:1: Medium ChangerNEC T40A2 0005 PQ: 0 ANSI: 2 [ 80.449402] ch 2:0:1:1: Attached scsi changer ch1 [ 80.449402] ch 2:0:1:1: Attached scsi generic sg6 type 8 [13387.819021] scsi 2:0:1:1: Med

[Bacula-users] update slots scan

2011-05-25 Thread Andre Lorenz
Hello together, i have a NEC-LTO4 (FC) 40 slots changer, and 8 slot LTO2 (8 Slots) changer (SCSI). this one was working perfectly. after physical move of the changers and servers i cant run anymore update slots scan on the LTO4 :-( on the old LTO2 i can run it without any problems. lsscsi will

Re: [Bacula-users] Perforce backups

2011-03-18 Thread Andre Lorenz
hi, sure, i can share ;-) there is no secret. most stuff is from perforce-kb / -documentation i have added lots links to p4 ;-) lets pick up one smaller server. p4-master (active-server) - /p4/database (size db.* 75GB) there i am running ususal scripts for che

Re: [Bacula-users] Perforce backups

2011-03-18 Thread Andre Lorenz
yes, i did ;-) how big is your p4 installation ? i have managed via hotspare-server p4-server (doing checkpoints) -> rsyncd (versionised files) --> p4hotspare --> tape db.files are replicated replicate-function in version 2010.1 on my side i will upgrade to 2010.2 which have backup and archivin

Re: [Bacula-users] FD not connecting to SD

2011-03-18 Thread Andre Lorenz
hi, just try to ass dir.conf Director{ DirAddress = 0.0.0.0 } sd.conf Storage { SDAddress = 0.0.0.0 } fd.conf FileDaemon { FDAddress = 127.0.0.1 } regards On 18.03.2011 09:00, Lawrence Strydom wrote: > Hi List, > > I have been tasked to test bacula as a possible backup solution

[Bacula-users] bacula is only running2 jobs

2011-02-09 Thread Andre Lorenz
Hello together, i have problem with "maximum current jobs". i have tried to change to various numbers. bacula is only running 2 jobs in parallel. also job priority is in every job the same. here is my setup. i have a nec LTO4 T40A2 auto changer connected via FC and one NEC LTO2 with one drive 8 s

[Bacula-users] getting volumes of a job

2011-01-27 Thread Andre Lorenz
Hello together, is there a possibility to get list of volumes which are used for specific job. e.g. which tapes / volumes are used for job RunOnce ? man thanks in advance. andre -- Special Offer-- Download ArcSight Logg