Hi All,
We have backup being taken for filesets of different users (users co-located on
a single Linux host as well as individual user with his/her private Linux host)
At the moment any user can restore other user's data through bconsole/BAT
How can we put some kind of ACL's to ensure that a giv
This error also occurs, when you have a tape library with n + 1 Drive, but
in the SD you only declare the 2nd or 3rd and not the main one.
Apparently for Bacula, the library needs to always have the Drive that it
considers main declared, usually Index 0.
On Tue, Jan 11, 2022 at 12:14 PM Tomasz Św
I find config error, in bacula-dir.conf is Media Type = LTO-8, in
bacula-sd.conf is Media Type = LTO8
Thanks
W dniu 2022-01-11 o 16:27, Heitor Faria pisze:
The baculi documentation discourages the use of LabelMedia = yes
with libraries
https://www.bacula.org/11.0.x-manuals/en/ma
> The baculi documentation discourages the use of LabelMedia = yes with
> libraries
> [ https://www.bacula.org/11.0.x-manuals/en/main/Basic_Volume_Management.html |
> https://www.bacula.org/11.0.x-manuals/en/main/Basic_Volume_Management.html ]
And I never undestood why...
Rgds.
--
MSc Heito
The baculi documentation discourages the use of LabelMedia = yes with
libraries
https://www.bacula.org/11.0.x-manuals/en/main/Basic_Volume_Management.html
W dniu 2022-01-11 o 15:59, Pedro Oliveira pisze:
Hi Tomasz,
Please could you change the following option on your device in your
BEE Stor
Unfortunately, the error is the same
W dniu 2022-01-11 o 15:59, Pedro Oliveira pisze:
Hi Tomasz,
Please could you change the following option on your device in your
BEE Storage Daemon Server Configuration file
The second change that is necessary to make automatic labeling work is
to give t
Set up a library of tapes in Bacula. I have a problem when I want to
label in bconsole.
* label barcode
3306 Issuing autochanger "slots" command.
Device "LibraryHP0" has 8 slots.
3306 Issuing autochanger "list" command.
The following Volumes will be labeled:
Volume slot
==
1 270011