Hello,
I'm getting my Quantum Dlt 4000 going with bacula. I've included my
definitions below and the job that i'm running. I'm not getting very good
performance with the spool, the drive starts and stops quite frequently, it
is on an Adaptec Ultrawide 2940 scsi controller. I was wondering th
Hello,
I'm trying to set up disk backup jobs. I've included my config at the
end of this msg, but i'm confused as to the difference between job
retention, and volume retention in the client definition, and volume
retention in the pool definition. I've read the bacula manual on these
topics,
Hello,
For anyone interested in doing regression testing, here is the procedure that I
recently sent to one interested FreeBSD user. If you are planning to do
regression testing, please let me and preferably the bacula-devel list know so
that we don't get too much duplication of effort -- pret
Hi all,
I am trying a second approach to understand how relabeling a tape
using the "relable" command from the console is supposed to work.
* I have a single tape drive setup, no autochanger.
* I am using bacula 2.0.3
* labeling tapes works fine
* backups work fine
* restores work fine
But
On Wednesday 11 April 2007 17:57:45 Michael Proto wrote:
> Any more ideas on getting the -fd to actually spit-out debug information
> is very welcome, and thanks again for all the help!
Are you running SELinux ? On recent RH platforms, you might want to
search /var/log/audit/audit.log and/or /va
Greetings,
the odd behavior might be caused by the SELinux policy. See below.
On Friday 30 March 2007 15:07:09 Kern Sibbald wrote:
> On Friday 30 March 2007 13:44, Christian Nolte wrote:
> > Kern Sibbald schrieb:
> > > Thanks for the patch.
> > >
> > > On Friday 30 March 2007 11:06, Christian Nolt
Hello,
As I have previously emailed several times over the last 6 months or so, I no
longer build Bacula on Solaris and FreeBSD, and other than testing the Win32
client, I am running no regression tests on Win32, Solaris and FreeBSD.
The Bacula community must step forward and organize system