On 31/03/2014 18:14, Octavio Alvarez wrote: > On 03/31/2014 07:34 AM, Stef wrote: >> the problem is coming from incorrect calibration by the backend. >> Gain is too high. Could you please run SANE 1.0.24 backend version with >> traces enabled, and send me log file and *.pnm files created during >> calibration ? >> In a command shell type: >> export SANE_DEBUG_GENESYS=255 >> export SANE_DEBUG_GENESYS_LOW=255 >> export SANE_DEBUG_GENESYS_GL646=255 >> export SANE_DEBUG_GENESYS_GL841=255 >> scanimage -d genesys --resolution 75 --preview --mode Color >> 2>preview.log >preview.pnm >> > I took some samples, even one with --resolution 150 and uploaded them here: > > http://blog.alvarezp.org/files/scan-hp3670/hp-sj3670-samples-1.tar.gz > > Some of those came out ok, some didn't. Only --resolution 150 threw out > a full set of pnm calibration files. --resolution 175 only threw out > warmup*.pnm files. > > > Hello,
thanks for all the data. It'll take me a couple of days to analyze them and compare with the results of my hp3670. Regards, Stef