Le mercredi 30 d?cembre 2009 10:04:02 Jochen Ehmen, vous avez ?crit :
> Am Mittwoch, den 30.12.2009, 08:41 +0100 schrieb stef:
> >     Hello,
> >
> >     the problem is surely due to incorrect detection of the sensor in your
> > scanner. Unfortunately debug messages didn't show what I need to fix this
> > issue. I have updated the lexmark backend to better log init time
> > information. What I need now is the debug log of the latest git source
> > version compiled and run with your scanner. You'll need to compile
> > sources (see
> > http://www.sane-project.org/source.html to get them), but installing the
> > backends isn't needed. You can test it in the sources'  backend
> > sub-directory with the following shell commands:
> >
> > export SANE_DEBUG_LEXMARK=255
> > export SANE_DEBUG_LEXMARK_LOW=255
> > export LD_PRELOAD=.libs/libsane-lexmark.so
> > ../frontend/.libs/scanimage 2>lexmark.log 1>lexmark.pnm
> >
> >     The debugging information I need will be in the lexmark.log file.
> >
> > Regards,
> >     Stef
> 
> Thank you!
> 
> I will do this and report back - but it will be some days until then.
> 
> What I do ask myself (and you - both rather rhethorical...) is: why does
> the older version work when there is missing info on the sensor?
> 
> All the best!
> 
> Jochen
> 
        Hello,

        the oldest version supported only one sensor. Some models like yours 
worked, 
others didn't.

Regards,
        Stef

Reply via email to