Hello Frank,
Frank Roberts - SOTL wrote: > Thanks for the help Peter. > > I did the following. > 1. Changed /dev/scanner to /dev/sg0 > 2. Made directory sane.d-bak > 3. removed all configuration files from sane.d except hp.conf don't remove the files. You need at least dll.conf too. And check that it has the line with hp activated. --Peter > 4 as root did chmood 666 /dev/sg0 > >>From this I would be happy to report glad tidings but alas this is not so. > I received exactly the same results - no change. > > Thanks > Frank > > On Sunday 04 August 2002 04:06, Peter Kirchgessner wrote: > >>Hi Frank, >> >>try the hp.conf with >> >>scsi HP >>/dev/sg0 >> >>If this does not work, you may have a second hp.conf at >>/etc/sane.d/hp.conf. Try that one with the same content. >>If it still does not work, do as root a >> >>chmod 666 /dev/sg0 >> >>and try it again. >> >>Sincerely >> >>Peter >> >>Frank Roberts - SOTL wrote: >> >>>Hi All: >>> >>>I hope You people will have time to help a relative novice with >>>configuration of an HP 6100 C which is to be used intermidently on 2 >>>different RH 7.3 systems. >>> >>> >>>As stated previously the scanner is an HP 6100C if I issue the command: >>>The scanner is connected by 40 pin scsi. >>>Several commands were issues with the following results: >>> >>>$ scanimage --list devices >>>sg0 HP C2520A 36644 >>>sg1 Mitsumi CD-R >>>sg2 Soney CD-RW >>> >>> >>>$ cat /proc/scsi/scsa >>>Attached devices: >>>Host: scsi0 Channel: 00 Id: 04 Lun: 00 Vendor: HP Model: C2520A Rev: 3644 >>>Type: Processor ANSI SCSI revision: 02 >>>Host: scsi1 Channel: 00 Id: 00 Lun: 00 Vendor: MITSUMI Model: CD-ROM >>>FX4830T!B Rev: R02C Type: CD-ROM ANSI SCSI revision: 02 >>>Host: scsi1 Channel: 00 Id: 01 Lun: 00 Vendor: SONY Model: CD-RW CRX175E2 >>>Rev: S002 Type: CD-ROM ANSI SCSI revision: 02 >>> >>> >>>$ export SANE_DEBUGG_HP=17 >>>$ scanimage -L >>>[scanei_debug] Setting debug level of hp to 17 >>>[hp] sane_init called[hp] >>>[hp] sane_init will finish with Success >>>[hp] sane_get_devices called >>>[hp] hp_read_config: hp backend v0.95 start reading conf file >>>[hp] hp_read_config: processing line <scsi HP> >>>[hp] hp_read_config: processing line </dev/scaner> >>>[hp] hp_read_config: attach scsi HP >>>[hp] hp_read_config: attach /dev/scanner >>>[hp] hp_get_dev: New device /dev/scanner, connect-scsi, scsi-request=1 >>>[hp] sanei_hp_device_new: /dev/scanner >>>[hp] scsi_newopen failed (Invalid argument) >>>[hp] /dev/scanner: Can't open scsi device >>>[hp] sane_get_devices will finish with Success >>>[hp] sane_exit called >>>[hp] sane_exit will finish >>> >>> >>>The sane configuration file /etc/sane.d/ho.conf is as follows: >>>scsi HP >>>/dev/scannet >>> >>>I would appreciate any advice you people may be able to offer. >>> >>>Thanks >>>Frank >>> >>>Thanks >>> >>> >>> >>>_______________________________________________ >>>Sane-devel mailing list >>>sane-de...@www.mostang.com >>>http://www.mostang.com/mailman/listinfo/sane-devel >>> > > _______________________________________________ > Sane-devel mailing list > sane-de...@www.mostang.com > http://www.mostang.com/mailman/listinfo/sane-devel > > -- Peter Kirchgessner http://www.kirchgessner.net mailto:pe...@kirchgessner.net