On 20/10/2021 22:00, Jeffrey Haas wrote:

On Oct 20, 2021, at 4:58 PM, Mahesh Jethanandani <mjethanand...@gmail.com> 
wrote:
On Oct 20, 2021, at 1:53 PM, Jeffrey Haas <jh...@pfrc.org 
<mailto:jh...@pfrc.org>> wrote:

There's also a note in the nits that the security considerations netconf 
boilerplate is pointing to older RFCs, but I haven't seen updated boilerplate 
issued?

See Section 3.7.1 of RFC 8407 here 
<https://datatracker.ietf.org/doc/html/rfc8407#section-3.7.1>.

Thank you, Mahesh.

Addressing this would close the remaining nits.

Manwhile  ...

Unless and until you register with IANA, you do not have a YANG module!

The web reference is ood and insecure

The title in the 'reference' clause is not that of the I-D

The text in the running footing is so long that it merges with prefix and suffix thereof

YANG augment are commonly accompanied by a 'when' to restrict their application.

Tom Petch