Look for burnt or hot spots near the top of the modules under the Jbox area. We 
have replaced a lot of modules of that age
Ameresco solar is supposedly making the replacement modules
Jeremy
All Solar
Sent via BlackBerry. Sorry for typos and shorthand!

-----Original Message-----
From: "SunHarvest" <e...@harvesthesun.com>
Sender: re-wrenches-boun...@lists.re-wrenches.orgDate: Sat, 21 Jul 2012 
13:19:13 
To: RE-wrenches<re-wrenches@lists.re-wrenches.org>
Reply-To: RE-wrenches <re-wrenches@lists.re-wrenches.org>
Subject: [RE-wrenches] Low power production at a winery: DC voltage drop