On Tue, Jan 18, 2011 at 12:29:40AM +0100, edgar.igles...@gmail.com wrote:
> From: Edgar E. Iglesias <edgar.igles...@gmail.com>
> 
> Break the TB after reading the count register. This makes it
> possible to take timer interrupts immediately after a read of
> a possibly expired timer.
> 
> Signed-off-by: Edgar E. Iglesias <edgar.igles...@gmail.com>
> ---
>  target-mips/translate.c |    4 +++-
>  1 files changed, 3 insertions(+), 1 deletions(-)
> 
> diff --git a/target-mips/translate.c b/target-mips/translate.c
> index cce77be..313cc29 100644
> --- a/target-mips/translate.c
> +++ b/target-mips/translate.c
> @@ -3410,8 +3410,10 @@ static void gen_mfc0 (CPUState *env, DisasContext 
> *ctx, TCGv arg, int reg, int s
>              gen_helper_mfc0_count(arg);
>              if (use_icount) {
>                  gen_io_end();
> -                ctx->bstate = BS_STOP;
>              }
> +            /* Break the TB to be able to take timer interrupts immediately
> +               after reading count.  */
> +            ctx->bstate = BS_STOP;
>              rn = "Count";
>              break;
>          /* 6,7 are implementation dependent */

This looks fine, however it should probably be done the same way for
dmfc0 on 64-bit MIPS.

-- 
Aurelien Jarno                          GPG: 1024D/F1BCDB73
aurel...@aurel32.net                 http://www.aurel32.net

Reply via email to