On Tue, Jan 18, 2011 at 12:29:40AM +0100, edgar.igles...@gmail.com wrote: > From: Edgar E. Iglesias <edgar.igles...@gmail.com> > > Break the TB after reading the count register. This makes it > possible to take timer interrupts immediately after a read of > a possibly expired timer. > > Signed-off-by: Edgar E. Iglesias <edgar.igles...@gmail.com> > --- > target-mips/translate.c | 4 +++- > 1 files changed, 3 insertions(+), 1 deletions(-) > > diff --git a/target-mips/translate.c b/target-mips/translate.c > index cce77be..313cc29 100644 > --- a/target-mips/translate.c > +++ b/target-mips/translate.c > @@ -3410,8 +3410,10 @@ static void gen_mfc0 (CPUState *env, DisasContext > *ctx, TCGv arg, int reg, int s > gen_helper_mfc0_count(arg); > if (use_icount) { > gen_io_end(); > - ctx->bstate = BS_STOP; > } > + /* Break the TB to be able to take timer interrupts immediately > + after reading count. */ > + ctx->bstate = BS_STOP; > rn = "Count"; > break; > /* 6,7 are implementation dependent */
This looks fine, however it should probably be done the same way for dmfc0 on 64-bit MIPS. -- Aurelien Jarno GPG: 1024D/F1BCDB73 aurel...@aurel32.net http://www.aurel32.net