Hi,

It seems like there's an extra Logging_collector check before calling
SysLogger_Start(). Note that the SysLogger_Start() has a check to
return 0 if Logging_collector is off. This change is consistent with
the other usage of SysLogger_Start().

                /* If we have lost the log collector, try to start a new one */
-               if (SysLoggerPID == 0 && Logging_collector)
+               if (SysLoggerPID == 0)
                        SysLoggerPID = SysLogger_Start();

Attaching a tiny patch to fix. Thoughts?

Regards,
Bharath Rupireddy.

Attachment: v1-0001-remove-extra-Logging_collector-check-before-SysLo.patch
Description: Binary data