Hi.
It does not work neitherway for me.

Is it out of bounds timing in the reset sequence that is the root cause?

What does the specification say?

I have an old 2 channel oscilloscope without storage capacity so it is
a bit difficult to measure timing of single events. 

Is it possible to make the interesting events repeatable?

Then what should I measure and what should I trigg on?

Olof

On Thu, 2010-08-05 at 05:45 +0200, Peter Stuge wrote:
> Freddie Chopin wrote:
> > In the config script of the target (lpc2148.cfg) replace:
> >
> > reset_config trst_and_srst
> >
> > with:
> >
> > reset_config trst_and_srst srst_pulls_trst
> 
> This reverts the patch I sent. I've used OpenOCD a lot both without
> the patch applied and with the patch applied, and can confidently say
> that LPC2148 operation is more stable with the patch applied. (I.e.
> without srst_pulls_trst.)
> 
> 
> //Peter
> _______________________________________________
> Openocd-development mailing list
> Openocd-development@lists.berlios.de
> https://lists.berlios.de/mailman/listinfo/openocd-development


_______________________________________________
Openocd-development mailing list
Openocd-development@lists.berlios.de
https://lists.berlios.de/mailman/listinfo/openocd-development

Reply via email to