Hi. It does not work neitherway for me. Is it out of bounds timing in the reset sequence that is the root cause?
What does the specification say? I have an old 2 channel oscilloscope without storage capacity so it is a bit difficult to measure timing of single events. Is it possible to make the interesting events repeatable? Then what should I measure and what should I trigg on? Olof On Thu, 2010-08-05 at 05:45 +0200, Peter Stuge wrote: > Freddie Chopin wrote: > > In the config script of the target (lpc2148.cfg) replace: > > > > reset_config trst_and_srst > > > > with: > > > > reset_config trst_and_srst srst_pulls_trst > > This reverts the patch I sent. I've used OpenOCD a lot both without > the patch applied and with the patch applied, and can confidently say > that LPC2148 operation is more stable with the patch applied. (I.e. > without srst_pulls_trst.) > > > //Peter > _______________________________________________ > Openocd-development mailing list > Openocd-development@lists.berlios.de > https://lists.berlios.de/mailman/listinfo/openocd-development _______________________________________________ Openocd-development mailing list Openocd-development@lists.berlios.de https://lists.berlios.de/mailman/listinfo/openocd-development